Note in the next step you will choose a new id. re, This jukebox, by default, assigns id 6 to the juke, Some host computer systems do not allow you to ass – HP Surestore 660ex Optical Jukebox User Manual
Page 58: Tables in appendix b show jukebox default settings, If another device id is placed between the jukebox, Press, If the jukebox is set to, (if using basic scsi addressing - lun mode off), Update, If the new settings do not conflict with other s
3-18
Chapter 3
Operating the Jukebox
Setting the SCSI IDs
NOTE
In the next step you will choose a new ID. Review this note.
This jukebox, by default, assigns ID 6 to the jukebox controller. When in LUN
mode, the jukebox controller ID uses LUN 0 for itself and assigns the drives on
Bus 1 to LUNs 1 to 4 or LUNs 1 to 6 (depending on whether you have four or
six drives on Bus 1 in your model of the jukebox).The result is that there are two
types of devices (controller and drives) at ID 6.
Some host computer systems do not allow you to assign different device types to
the same ID. If your host computer system does not support multiple types at the
same ID and you want to use LUN mode, you must select different IDs for the
jukebox controller (
JKBX ID #
) and the drives (
DRV #
).
Tables in Appendix B show jukebox default settings and an example of setting
the jukebox controller and drives to different IDs (one digit apart).
If another device ID is placed between the jukebox controller and the drives,
problems can result. For this reason, the jukebox will not accept IDs for the jukebox
controller and drives that are more than one digit apart. You will receive a
CONFLICT
message.
6. Press
NEXT
or
PREV
until the new ID that you want displays and then press
ENTER
.
If the jukebox is set to
LUN MODE ON
, go to Step 8. Only one ID can be
changed and the ID automatically updates when you press
ENTER
.
7. (If using basic SCSI addressing - LUN mode OFF) Press
NEXT
until
UPDATE
displays, and then press
ENTER
.
8.
UPDATE
or
WAIT FOR UPDATE
and then
ID’S SAVED
displays briefly.
•
If the new settings do not conflict with other SCSI IDs on the bus,
SCSI
ID’S
displays.
•
If the new settings conflict with other IDs on the SCSI bus,
CONFLICT-ABORTED
displays briefly and then
VIEW ID’S
displays.
Any changes entered are lost, and you must repeat steps 3 through 6 to set a
new ID.
NOTE
When in LUN mode:
If the new ID you choose results in the IDs for the jukebox controller and the drives
being more than one digit apart, the jukebox displays
CONFLICT
and rejects the ID.
9. Press
CANCEL
until
READY
displays.