Read and save these instructions, 20" whole house window fan, Save these instructions

background image

20" WHOLE HOUSE WINDOW FAN

20" (50.8 cm) MODEL 3C614D/9166D

MODEL

3C614D/9166D

SPEED HIGH

MED

LOW

CFM

3560

3120

2510

M

3

/s

1.68

1.47

1.18

RPM

1600

1450

1100

Amps 1.4

1.2

1.0

Watts 170

145

115

dB A

64

57

50

MODEL/MODELO/MODELE 3C614D/9166D

DESCRIPTION

The Air King® 20" (50.8 cm) Whole House Window Fan features three
intake and three exhaust speeds. Fan will fit windows 27" (68.6 cm) to
38" (96.5 cm) wide x 26-1/4" (67.3 cm) high. The adjustable side panels
are designed to accommodate Fan mounting either inside or outside
interior window trim. The 3-paddle Fan blade is driven by a permanently
lubricated, permanent split capacitor motor with 6' (1.8 m), 18/3 cord
set.

SPECIFICATIONS

Motor ...................................... 120V, 50/60 Hz
Blade diameter ....................... 20" (50.8 cm)
Speeds .................................... 3 Intake, 3 Exhaust
Control .................................... Rotary Switch
Approvals ................................ ETL Listed. Close mesh Fan guard

meets OSHA requirements.

GENERAL SAFETY INFORMATION

When using electrical appliances, basic precau-

tions should always be followed to reduce the risk

of fire, electric shock and injury to person, includ-

ing the following:

1. Read all instructions before using Fan.
2. Make certain that the power source conforms to the electrical

requirements of the Fan.

3. Use this Fan only as described in this manual. Any other use

not recommended by the manufacturer may cause fire, electrical

shock, or injury to persons.

4. Unplug power cord before installing, servicing, or moving the

Fan.

WARNING:

DO NOT DEPEND UPON THE ON-OFF

SWITCH AS THE SOLE MEANS OF DISCONNECTING
POWER WHEN INSTALLING OR SERVICING THE FAN.
ALWAYS UNPLUG THE POWER CORD.

5. This Fan must NOT be used in potentially dangerous

locations such as flammable, explosive, chemical-laden

or wet atmospheres.

6. The power cord is equipped with a three-prong grounded plug

that must be inserted into a matching receptacle. Under no

circumstances must the grounding prong be cut off the plug.

Where a two-prong wall receptacle is encountered, it must be

replaced with a properly grounded three-prong receptacle in-

stalled in accordance with the National Electrical Code (NEC)

and all applicable local codes and ordinances. This work must

be done only by a qualified electrician, using copper wire only.

Contact your Grainger Distributor.

WARNING:

USE OF A THREE-PRONG TO TWO-PRONG

ADAPTER IS NOT RECOMMENDED. IMPROPER CONNEC-
TION MAY CREATE THE RISK OF ELECTROCUTION. USE
OF SUCH ADAPTERS IS NOT PERMITTED IN CANADA.

7. Where possible, avoid the use of extension cords. If they must

be used, minimize the risk of overheating by ensuring that they

are UL listed. Never use a single extension cord to operate

more than one Fan.

8. Do not operate any Fan with a damaged cord or plug or

after the Fan malfunctions, has been dropped or damaged

in any manner. Return Fan to authorized service facility for

examination, electrical or mechanical adjustment or repair.

9. Do not insert or allow fingers or foreign objects to enter any

ventilation or exhaust opening as it may cause an electric shock

or fire, or damage the Fan. Do not block or tamper with the

Fan in any manner while it is in operation.

10.Always place the Fan on a stable, flat, level surface when

operating, to avoid the chance of the Fan overturning. Locate

the Power Cord so the Fan or other objects are not resting on it.

Do not run Power Cord under carpeting. Do not cover Power

Cord with throw rugs, runners, or the like. Arrange Power Cord

away from room traffic and where it will not be tripped over.

11.This Fan is not intended for use in wet or damp locations.

Never locate a Fan where it may fall into a bathtub or other

water container.

12. Do not use Fan outdoors.
13.This Fan is not suitable for use in agricultural facilities including

areas where livestock, poultry or other animals are confined.

Please refer to National Electric Code (NEC) Article 547-7

(2008), or applicable state or local codes or standards relating

to electrical requirements for Agricultural Buildings. THIS FAN

DOES NOT MEET THE REQUIREMENTS OF NEC ARTICLE

547-7 (2008).

14. This Fan is not suitable for use in hazardous locations. Please

refer to National Electric Code (NEC) Article 500 or applicable

state or local codes or standards relating to electrical

requirements for Hazardous locations. THIS FAN DOES NOT
MEET THE REQUIREMENTS OF NEC ARTICLE 500 (2008).

WARNING:

REDUCE THE RISK OF FIRE OR

ELECTRIC SHOCK – DO NOT USE THIS FAN WITH ANY
SOLID STATE SPEED CONTROL DEVICES.

SAVE THESE INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS

READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DE-

SCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY

WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!

RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.

OPERATING INSTRUCTIONS & PARTS MANUAL

Rev. J 12/07

8

2085109A

Rev. J 12/07

1

2085109A

+

+

+

+

0

1

2

3

20

2

21

12

11

10

20

9

8

7

22

5

19

4

3

2

1

17

LISTE DES PIECES DE REMPLACEMENT

Clé

No de Pièce

Description

Qte

1

02030113

Moteur Assemblage

1

2

2090008

Vis #8 x 1,27 cm de type PPH 25 ZP

24

3

05097110CG Grille intérieure

1

4

5090045

Vis #10-32 x 1,27 cm HWH Serr F-ZP

3

5

5082090CH

Lame

1

7

2010722

Bâti

1

8

05097100CG Grille extérieure

1

9

02084613

Plaque centrale

1

10

2060087

Panneau latéral

2

11

02090508

Guide en caoutchouc

4

12

2060086

Canal

2

17

05010109

Bouton de l’interrupteur

1

19

5090044

Vis de réglage 0,64 cm 28 x 0,95 cm

1

20

2091413

Vis à bois #8 x 1,91 cm

4

21

2084076

Gabarit

1

22

2090024

Vis #8 x 1,91 cm PPH de type 25 ZP

4

This manual is related to the following products: