SPECIFICATIONS

HEAT/VENT/LIGHT

AKF965

70 CFM/4.0 SONES @ 0.10" WG. -HVI CERTIFIED

120 Volts, 14.2 amps, 60 hz.

Grill

White, round polymeric grill (flame retardant ABS UL rated 94-
5V) secured in place using 2 Philip's head screws, easily removed
if necessary, dimensions - 17

1/8

" x 9

7/8

".

• Light Lens

Moonstone glass lens, secured in a flip down lens holder. Secured
in place using integral tabs.

• Blower Wheels

Heater Blower Wheel: One piece metal, electronically

balanced, 3

5/8

" x 2" with 28 fins

Ventilation Blower Wheel: One piece polymeric, electronically

balanced 3

7/8

" x 2

1/2

" with 21 fins.

• Motors

Heater Motor: Heavy duty, plug-in 2 pole motor. Life time

lubrication, thermally protected. Rated 120 volts,
60 hz., 0.90 amps, 2400 rpm.

Ventilation Motor: Heavy duty, plug-in 2 pole motor. Life time

lubrication, thermally protected.
Rated 120 volts, 60 hz., 0.90 amps

• Heater Housing

23 ga. galvanized steel housing, dimensions 14

5/8

" x 9

1/8

" x 7

1/8

"

• Heating Element

Wire coil, secured in place by ceramic “J” shaped hooks and
terminated by bolt and nut in cylindrical standoffs. Housed in an
all metal enclosure. Rated 1500 watts - 5120 BTU.

• Duct Collar

Metal collar for 4" duct connection, comes complete with built
in metallic back draft damper.

CUL/HVI - TYPE IC RATED

Canada: 110 Glidden Road
Brampton, Ontario L6T 2J3
Tel: (905) 456-2033
Fax: (905) 456-1015

U.S.: 820 Lincoln Drive
West Chester, Pennsylvania 19380-4466
Tel: (610) 692-7400 • 877-304-3785
Fax: (610) 696-8048

Updated 3-06

Specifications subject to change without notice.

• Lamping Information

Main Lighting: Electronic Quick Start Ballast – rated 26 Watt

Use Triple 4 pin PL lamp. Maximum 26 Watt.
High Efficacy electronic ballast meets California
lighting efficiency requirements.

Night Lighting: 7 watt maximum, type C7, Candelabra base bulb

• Unit Mounting

Rated Type IC for ceilings insulated to R-40. Designed to mount
in ceilings with at least 6" of clearance. The unit will mount
between joists (with 16" centers) or butted up against a joist.
The housing will mount through drywall thickness up to

3/4

",

with a rough-in opening of 14

13/16

" x 9

1/4

".

• Ventilating Area

For bathrooms up to 70 sq. ft. for other rooms up to 85 sq. ft.

• Single Pack Shipping Info

Box Dim Box Dim: 21.5" x 11.5" x 9.5"
UPC: 0-8316290039-5
Shipping Weight: 16 lbs.

C

US

Air-King exhaust fans are tested by the Air Movement and Control Association (AMCA) in accordance with HVI test standard 916, (Air Flow Test Standard) and HVI test standard
915 (Procedure For Loudness Rating Of Residential Fan Products). The Performance results are certified and verified by the Home Ventilating Institute (HVI).

PROJECT

LOCATION

CONTRACTOR

ARCHITECT

ENGINEER

SUBMITTED BY

DATE

FAN

MODEL

CFM

IN

RPM

WATTS

AMPS

SONES

QTY

OPTIONAL EQUIPMENT

NUMBER NUMBER

W.G.

& REMARKS

PERFORMANCE

HVI Sones

Fan Speed

Power

Static Pressure (inches of w.g.)

@ .1 SP

RPM

Watts

0

0.05

0.1

0.125

0.15

0.2

0.25

0.3

Air Flow - CFM

77

74

71

69

68

65

61

57

4.0

2450

51