beautypg.com

Air King 4C630P/9012P User Manual

Read and save these instructions, Wall mounted oscillating fans, Save these instructions

background image

14

1

3

21

22

23

24

25

26

9

8

6

12

11

18

7

13

20

15

16

17

18

2

4

3

19

10

5

DESCRIPTION

Air King® 12" (30,4 cm) and 16" (40,6 cm) Wall Mounted Oscillating

Fans offer rotary knob/pull cord speed control, variable oscillation,

a permanent split capacitor motor and OSHA-complying front steel

mesh grill with a 6 ft (1,8m) 18/3 cord set.

SPECIFICATIONS

Motor .................................120V, 60 Hz (12" 30,4 cm)

120V, 60 Hz (16" 40,6 cm)

Blade diameter ...................12" ( 30,4 cm) Model 4C630P/9012P

16" (40,6 cm) Model 4C631Q/9016Q

Speeds ...............................3

Control ...............................Rotary Knob/Pull Cord

Air flow distribution ...........90°

Approvals ...........................ETL Listed. Close mesh Fan Guard

meets OSHA requirements.

1

2084077

Rev. G 9/09

WALL MOUNTED

OSCILLATING FANS

12" (30,4 cm) MODEL 4C630P/9012P

16" (40,6 cm) MODEL 4C631Q/9016Q

8

2084077

Rev. G 9/09

MODELO 4C630P/9012P y 4C631Q/9016Q

GENERAL SAFETY INFORMATION

When using electrical appliances, basic precautions should

always be followed to reduce the risk of fire, electric shock

and injury to person, including the following:

1. Read all instructions before using Fan.
2. Make certain that the power source conforms to the electrical

requirements of the Fan.

3. Use this Fan only as described in this manual. Any other use

not recommended by the manufacturer may cause fire, electrical

shock, or injury to persons.

4. Unplug power cord before installing, servicing, or moving the

Fan.

WARNING: DO NOT DEPEND UPON THE ON-OFF SWITCH

AS THE SOLE MEANS OF DISCONNECTING POWER WHEN

INSTALLING OR SERVICING THE FAN. ALWAYS UNPLUG THE

POWER CORD.
5. This Fan must NOT be used in potentially dangerous

locations such as flammable, explosive, chemical-laden

or wet atmospheres.

6. DO NOT use Fan in or near a window. Rain may create an

electrical hazard.

7. The power cord is equipped with a three-prong grounded

plug that must be inserted into a matching receptacle. Under

no circumstances should the grounding prong be cut off the

plug. Where a two-prong wall receptacle is encountered, it

must be replaced with a properly grounded three-prong re-

ceptacle installed in accordance with the National Electrical

Code (NEC) and all applicable local codes and ordinances.

This work must be done only by a qualified electrician, using

copper wire only.

WARNING: USE OF A THREE-PRONG TO TWO-PRONG ADAPTER

IS NOT RECOMMENDED. IMPROPER CONNECTION MAY CRE-

ATE THE RISK OF ELECTRIC SHOCK. USE OF SUCH ADAPTERS

IS NOT PERMITTED IN CANADA.

WARNING: THIS PLUG IS A SAFETY FEATURE. TO REDUCE

THE RISK OF FIRE, ELECTRIC SHOCK AND PERSONAL INjURY,

DO NOT REMOVE, REPLACE, REPAIR OR TAMPER WITH

THE ORIGINALLY SUPPLIED PLUG. IF THE FAN DOES NOT

FUNCTION PROPERLY, IT MAY bE DUE TO THE SAFETY DEVICE

INCORPORATED IN THIS PLUG.

8. Where possible, avoid the use of extension cords. If they must

be used, minimize the risk of overheating by ensuring that they

are UL listed. Never use a single extension cord to operate more

than one Fan.

9. NEVER operate any Fan with a damaged cord or plug or after

the Fan malfunctions, has been dropped or damaged in any

manner.

10.Do not insert or allow fingers or foreign objects to enter any

ventilation or exhaust opening as it may cause an electric shock

or fire, or damage the Fan. Do not block or tamper with the Fan

in any manner while it is in operation.

11.Always place the Fan on a stable, flat, level surface when

operating, to avoid the chance of the Fan overturning. Locate

the Power Cord so the Fan or other objects are not resting on it.

Do not run Power Cord under carpeting. Do not cover Power

Cord with throw rugs, runners, or the like. Arrange Power Cord

away from room traffic and where it will not be tripped over.

12.This Fan is not intended for use in wet or damp locations. Never

locate a Fan where it may fall into a bathtub or other water

container.

13.Do not use Fan outdoors.
14.This Fan is not suitable for use in agricultural facilities including

areas where livestock, poultry or other animals are confined.
Please refer to National Electric Code (NEC) Article 547-7
(2008), or applicable state or local codes or standards relating
to electrical requirements for Agricultural Buildings. THIS FAN
DOES NOT MEET THE REQUIREMENTS OF NEC ARTICLE
547-7 (2008).

15.This Fan is not suitable for use in hazardous locations. Please

refer to National Electric Code (NEC) Article 500 or applicable
state or local codes or standards relating to electrical
requirements for Hazardous locations. THIS FAN DOES NOT
MEET THE REQUIREMENTS OF NEC ARTICLE 500 (2008).


WARNING:

REDUCE THE RISK OF FIRE OR ELECTRIC

SHOCK – DO NOT USE THIS FAN WITH ANY SOLID
STATE SPEED CONTROL DEVICES.

SAVE THESE INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS

READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DE-

SCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY

WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!

RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.

OPERATING INSTRUCTIONS & PARTS MANUAL

LISTA DE REPUESTOS

1

2060316

2060316

Placa de Montaje

1

2

2090003

2090003

Tornillo Phillips #8 x 1-1/4"

2

3

02090045A

02090045A

Tornillo Phillips Tipo 25 #8 x 3/4" 6

4

02090272

02090272

Pata de Caucho

2

5

2060202

2060202

Placa Tracera para Colgar

1

6

2010554

2010554

Tapa del Interruptor

1

7

2090008

2090008

Tornillo Phillips #8 x 1/2"

2

8

02055047

02055047

Interruptor con Cordón

Accionador

1

9

7091854

7091854

Plastico Protector

2

10 2010512P

2010512P

Cuerpo

1

11 2090539

2090539

Casquillo del Cordón Accionador 1

12 02090744

02090744

Tire Cuerda

1

13 02035035

02035036

Conjunto de Motor

1

14 02010162B

02010162B

Placa de Trinquete

1

15 02090518

02090518

Resorte de Elevación

1

16 02090521A

02090521A

Eje de Elevación

1

17 02090033

02090033

Tuerca Hexagonal

1

18 02010548A

02010548A

Boton Tipo H.C.

2

19 2010131

2010131

Botón del Interruptor (Rotatorio) 1

20 02050009FPB

02050009FPB

Cordón Eléctrico

1

21 2011212

2011200M

Rejilla Plástica Trasera

1

22 2010359

2010359

Tuerca de Seguridad

1

23 2010008

2011013

Aspa

1

24 2010058

2010090

Tapa

1

25 02096217

02096214

I

Rejilla Frontal

1

26 02010381A

02010381A

Ornamento

1

Ref.

Parte No. for Modelo

No. 4C630P/9012P

4C631Q/9016Q

Descripción

Cant.

24

2

7

MODEL

4C630P/9012P

4C631Q/9016Q

SPEED

HIGH

MED

LOW

HIGH

MED

LOW

CFM

940

800

700

1510

1380

1190

M

3

/s

0.44

0.38

0.33

0.71

0.65

0.56

RPM

1470

1320

1100

1411

1280

1110

Amps

0.46

0.37

0.32

0.80

0.57

0.47

Watts

51

44

39

87

70

57

dBA

45

41

36

51

47

42