beautypg.com

San diagnostic logs, Firmware prerequisites for sfp diagnostics, Firmware – HP Intelligent Infrastructure Analyzer Software Licenses User Manual

Page 22: Firmware prerequisites

background image

Click Delete to delete the selected event log.

Click the Advanced Search option, to search events based on different criteria.

Select ALL or specific event severity to perform a search accordingly.

Select the Start Date, End Date and Component and click Search.

NOTE:

Search on a Component name does not include its sub-components logs in the

list.

Click Delete to delete the selected searched events.

Click Clear to clear the data entered to search.

Click Back to go back to the SAN Event Logs page.

NOTE:

The delete operation deletes the entry permanently and it is an unrecoverable

operation.

Figure 10 Event log – Advanced search

SAN Diagnostic Logs

IIAS diagnoses the SFPs which are detected to be degrading or failing. The HP IIAS monitors
following five parameters of an SFP:

1.

Transmit Power

2.

Receive Power

3.

Voltage

4.

Current

5.

Temperature

As part of diagnostics, above values (collected during data collection) are compared against the
threshold specification range. Threshold specification range varies based on vendor, model and
property being monitored. If the values collected are found outside the threshold range, HP IIAS
raises diagnostics events for such SFP. HP IIAS raises a separate diagnostics event for each
parameter.

NOTE:

For embedded Blade SAN Switch, only SFPs of external ports are monitored.

Diagnostic happens only when the I/O (Input or output) operation occurs on the SFP or if SFP
is in failed state.

Firmware prerequisites for SFP diagnostics

SFP monitoring and diagnostics requires:

A B-Series switch that has firmware version 7.x or later.

A H-Series switch that has firmware version 8.0.14.03.00 or 8.0.4.04.00 or higher.

22

Using HP IIAS