Host – HP StorageWorks XP Remote Web Console Software User Manual
Page 36

Table 2 Host Mode Options
When to select this option
Host mode options
No.
When VERITAS Database Edition/Advanced Cluster for Real Application Clusters
or VERITAS Cluster Server 4.0 or later (I/O fencing function) is used
VERITAS Database
Edition/ Advanced
Cluster
2
When all the following conditions are satisfied:
•
The host mode 0C Windows or 2C Windows Extension is used
•
The Emulex host bus adapter is used
•
The mini-port driver is used
•
TPRLO=2 is specified for the mini-port driver parameter of the host bus
adapter
TPRLO
6
When all the following conditions are satisfied:
•
The host mode 00 Standard or 09 Solaris is used
•
SUN StorEdge SAN Foundation Software Version 4.2 or better is used
•
You want to automate recognition of increase and decrease of devices when
genuine SUN HBA is connected
Automatic recognition
function of LUN
7
When all the following conditions are satisfied:
•
The host mode 08 HP is used
•
You want to suppress creation of device files for devices to which paths are
not defined.
No display for ghost
LUN
12
When you want to be informed by SIM (service information message) that the
number of link failures detected between ports exceeds the threshold
SIM report at link failure
13
1
When all the following conditions are satisfied:
•
The host mode 07 Tru64 is used
•
You want to use TruCluster to set a cluster to each of P-VOL and S-VOL for
XP Continuous Access or HP StorageWorks XP Continuous Access Journal
Software.
HP TruCluster with XP
Continuous Access
function
14
When all the following conditions are satisfied:
•
The host mode 0F AIX is used
•
HACMP 5.1 Version 5.1.0.4 or later, HACMP4.5 Version 4.5.0.13 or later,
or HACMP5.2 or later is used
HACMP
15
When Veritas Cluster Server is used.
Veritas Cluster Server
22
When you want to shorten the recovery time on the host side if the data transfer
failed.
REC Command Support
23
1
When all the following conditions are satisfied:
•
The host mode 03 HP or 05 OpenVMS
2
is used.
•
You want to enable commands to assign a nickname of the device.
•
You want to set UUID to identify a logical volume from the host
Set/Report Device
Identifier enable
33
When all the following conditions are satisfied:
•
The host mode 05 OpenVMS or 07 Tru64 is used
•
You want to set UUID to identify a logical volume from the host.
UUID Option
34
In case that you want to control the following ranges per host group when
receiving Target Reset:
•
Range of job resettings
•
Range of UAs (Unit Attentions) defined
Change the nexus
specified in the SCSI
Target Reset
39
36
Performing LUN Manager Operations