beautypg.com

Configuration overview, Adding the control path and data path, Server – HP Integrity NonStop H-Series User Manual

Page 55

background image

SL500 (M852x) Tape Library Installation and User’s Guide541531-010

7 -1

7

Configuring the M8521 Tape

Library for the NonStop S-Series
Server

The section covers:

Configuration Overview

You can attach the tape library (control path and data path) to a NonStop S-series

server via an IOAM enclosure. The tape library attaches to the FCSA (Fibre Channel

ServerNet adapter) in the IOAM enclosure. The ServerNet switch board on the IOAM

enclosure connects to a MSEB (Modular ServerNet Expansion Board) on a NonStop S-

series server via a fiber-optic cable.

For more information on the IOAM enclosure, see the

Modular I/O Installation and

Configuration Guide

.

Adding the Control Path and Data Path

To add the control path, issue this SCF command:

SCF> ADD SCSI $device, SENDTO STORAGE, PRIMARYLOCATION
(group, module, slot), PRIMARYSAC sac-id, LUN lun-id,
PRIMARYPORT 64-bit-portname

Example:

SCF> ADD SCSI $M8521, SENDTO STORAGE, PRIMARYLOCATION
(110,2,2), PRIMARYSAC 2, LUN 0, PRIMARYPORT 1234567891234567

Configuration Overview

7-1

Adding the Control Path and Data Path

7-1

Note.

The control path is used to control the robot, and the data path is used to control the

tape drive (M8504).

Note.

The portname numbers used in this section are examples only.

.

This manual is related to the following products: