beautypg.com

4 troubleshooting – HP Insight Control Software for Linux User Manual

Page 29

background image

4 Troubleshooting

Insight Control power management fails to show the Power graph and I receive
the message

Insight Control power management could not communicate with

the Management Processor as it is not accessible.

Solution: One of the following could be the reason for getting the above mentioned message.

Connection to Management Processor timed out due to network problem or Management Processor
being unreachable.

Mismatch of SSL ports between power management and management processor.

Please make sure that these problems are resolved.

My power management supported system is being listed as

System is not

supported by Insight Control power management.

Solution: Take the following steps to resolve the problem:

1.

Verify that your system is indeed supported by the version of power management you have installed,
and that you are running the required iLO firmware versions on the managed systems. To access the
latest power management support matrix information, see

HP Insight Software Support Matrix available

at:

http://www.hp.com/go/insightcontrol/docs

. To view power management version information, select

Help

About Insight Control power management.

2.

Check to see that the management processor is discovered and associated with the system.

NOTE:

Server Management Processor

association is a must to be able to view the power details

in power management.

3.

Insight Control power management identifies the system as power management supported system. If
power management does not identify the system, run the Identification Task on both the system and
its management processor by selecting Options

Identify Systems.

Running the Identification Task will help power management to recognize the system as a power
management supported system.

Insight Control power management has failed to fetch the Power details and
a message is displayed indicating

Unable to communicate with iLO 2 because

it does not have an iLO 2 Advanced or iLO 2 Select license.

Solution: Take the following steps to resolve the problem:

1.

Launch the iLO 2 web interface and assign the Advanced/Select license if the iLO 2 is not already
licensed.

2.

Check to be sure the iLO 2 is associated with its system.

3.

Launch the Deploy

License Manager by selecting the iLO 2 as target and click on Collect license

info...

.

4.

Select Deploy

License Manager to verify the iLO 2 is listed as the licensed system under the HP iLO

Advance Pack

or the HP iLO Select Pack category.

NOTE:

iLO 2 must appear as a licensed system in the License Manager to view the Power details from

power management.

5.

Launch the power management page on that system and click Refresh Data to view the latest power
details.

Insight Control power management fails to show the Power graph and I receive the message Insight Control power management

could not communicate with the Management Processor as it is not accessible.

29