Array configuration utility – HP Smart Array B110i SATA RAID-Controller User Manual
Page 7
Enabling and configuring the controller 7
6.
Press the F8 key to confirm the settings and save the new configuration.
After several seconds, the Configuration Saved screen appears.
7.
Press the Enter key to continue.
Repeat this procedure to create additional logical drives.
Array Configuration Utility
ACU is a browser-based utility with the following features:
•
Runs as a local application or remote service
•
Supports assignment of online spares
•
Suggests the optimum configuration for an unconfigured system
•
Provides different operating modes, enabling faster configuration or greater control over the
configuration options
•
Remains available any time that the server is on
•
Displays on-screen tips for individual steps of a configuration procedure
•
Beginning with ACU version 8.28.13.0, provides diagnostic functionality on the Diagnostics tab
(formerly known as Array Diagnostics Utility)
For optimum performance, the minimum display settings are 1024 × 768 resolution and 16-bit color.
Servers running Microsoft® operating systems require one of the following supported browsers:
•
Internet Explorer 6.0 or later
•
Mozilla Firefox 2.0 or later
For Linux servers, see the README.TXT file for additional browser and support information.
For more information, refer to the Configuring Arrays on HP Smart Array Controllers Reference Guide on
the Documentation CD or the HP website
Installing the HP Smart Array Hot Plug Advanced
Pack for B110i license key
When installed and activated, the HP Hot Plug Advanced Pack license key enables the user to remove
and install hard drives without powering down the server.
For proper hot-plug operation, the following items are required:
•
The HP Hot Plug Advanced Pack license key
•
A drive cage backplane configured for the B110i SATA RAID controller
•
A supported hard drive installed in the server
•
One of the following drivers, depending on the operating system:
o
Microsoft® Windows® driver version 6.10.x or later
o
Red Hat Enterprise Linux driver version 1.2.4-x or later
o
Novell SUSE SLES driver version 1.2.4-x or later
- ProLiant ML110 G6 Server ProLiant DL120 G6 Server ProLiant SL2x170z G6 Server ProLiant SL170z G6 Server ProLiant BL280c G6 Server-Blade ProLiant DL160se G6 Server ProLiant SL160z G6 Server ProLiant DL180 G6 Server ProLiant DL160 G6 Server ProLiant DL170h G6 Server ProLiant ML330 G6 Server ProLiant SL165z G7 Server ProLiant DL165 G7 Server ProLiant DL320 G6 Server