Power supply module voltage sensors, 11 power supply temperature sensors, 12 voltage sensor descriptions – HP P2000 G3 MSA Array Systems User Manual
Page 63

HP P2000 G3 FC MSA System User Guide
63
When a power supply sensor goes out of range, the Fault/ID LED illuminates amber and an event is
logged to the event log.
Power supply module voltage sensors
Power supply voltage sensors ensure that an enclosure’s power supply voltage is within normal ranges.
There are three voltage sensors per power supply.
Onboard temperature 2
0–70°C
None
None
None
Onboard temperature 3
(Capacitor temperature)
0–70°C
None
None
None
CM temperature
5–50°C
≤
5°C,
≥
50°C
≤
0°C,
≥
55°C
None
Table 11
Power supply temperature sensors
Description
Normal operating range
Power Supply 1 temperature
–10–80°C
Power Supply 2 temperature
–10–80°C
Table 10
Controller module temperature sensors (continued)
Description
Normal operating
range
Warning
operating range
Critical operating
range
Shutdown values
Table 12
Voltage sensor descriptions
Sensor
Event/Fault LED condition
Power supply 1 voltage, 12V
< 11.00V
> 13.00V
Power supply 1 voltage, 5V
< 4.00V
> 6.00V
Power supply 1 voltage, 3.3V
< 3.00V
> 3.80V