beautypg.com

Testing enclosure connections, Powering on/powering off, Power supply – HP P2000 G3 MSA Array Systems User Manual

Page 33: 11 ac psu

background image

HP P2000 G3 FC MSA System User Guide

33

Testing enclosure connections

NOTE:

Once the enclosures’ power-on sequence succeeds, the storage system is ready to be connected to

hosts, as described in

Connecting the enclosure to data hosts

on page 37.

Powering on/powering off

Before powering on the enclosure for the first time:

Install all disk drives in the enclosure so the controller can identify and configure them at power-up.

Connect the cables and power cords to the enclosures as explained in the installation sheet.

NOTE:

P2000 G3 controller enclosures and some P2000 G3 drive enclosures do not have power

switches. They power on when connected to a power source, and they power off when disconnected.

Generally, when powering up, make sure to power up the enclosures and associated data host in the

following order:
• Drive enclosures first

This ensures that disks in the drive enclosure have enough time to completely spin up before being

scanned by the controller modules within the controller enclosure.
While enclosures power up, their LEDs blink. After the LEDs stop blinking — if no LEDs on the front

and back of the enclosure are amber — the power-on sequence is complete, and no faults have

been detected. See

LED descriptions

on page 65 for descriptions of LED behavior.

• Controller enclosure next

Depending upon the number and type of disks in the system, it may take several minutes for the

system to become ready.

• Data host last (if powered down for maintenance purposes).

TIP:

Generally, when powering off, you will reverse the order of steps used for powering on.

Power supply

Many controller and expansion enclosures rely on the power cord for power cycling. Connecting the cord

from the PSU power cord connector to the appropriate power source facilitates power on; whereas

disconnecting the cord from the power source facilitates power off.

Figure 11

AC PSU

To power on the system:

1.

Obtain a suitable AC power cord for each AC PSU that will connect to a power source.

Power cord connect

This manual is related to the following products: