Redundant fans option, Redundant fan guidelines – HP ProLiant ML350p Gen8 Server User Manual

Page 85

background image

Hardware options installation 85

o

Cache module on the Smart Array option

12.

Install the fan cage.

13.

Install the air baffle (on page

26

).

14.

Install the access panel (on page

24

).

15.

Do one of the following:

o

For tower models, return the server to an upright position.

o

For rack models, slide the server back into the rack.

16.

Connect each power cord to the server.

17.

Connect each power cord to the power source.

18.

Press the Power On/Standby button.
The server exits standby mode and applies full power to the system. The system power LED changes

from amber to green.

19.

Do one of the following:

o

For tower models, install the bezel.

o

For rack models, if removed, install the security bezel (on page

21

).

Redundant fans option

Redundant fan guidelines

The server supports redundant fans to provide proper airflow to the system when a primary fan fails.
In the standard, nonredundant configuration, fans 2, 3, and 4 cool the server.
For the redundant configuration, fan 1 and four fan louvers are added to back up the primary fans. This

configuration enables the server to continue operation in redundant mode, when a fan failure occurs. In a

redundant fan configuration:

If one fan fails, then the other three fans provide airflow.