beautypg.com

HP ProLiant ML350p Gen8 Server User Manual

Page 106

background image

Hardware options installation 106

WARNING:

To reduce the risk of personal injury, electric shock, or damage to the equipment,

remove the power cord to remove power from the server. The front panel Power On/Standby

button does not completely shut off system power. Portions of the power supply and some internal
circuitry remain active until AC power is removed.

WARNING:

To reduce the risk of personal injury from hot surfaces, allow the drives and the

internal system components to cool before touching them.

1.

Do one of the following:

o

For tower models, open and remove the bezel ("

Remove the tower bezel

" on page

21

).

o

For rack models, if installed, remove the security bezel (on page

21

).

2.

Power down the server (on page

20

).

3.

Remove all power:

a.

Disconnect each power cord from the power source.

b.

Disconnect each power cord from the server.

4.

Do one of the following:

o

For tower models, place the server on a flat, level surface with the access panel facing up.

o

For rack models, extend the server from the rack (on page

24

).

5.

Remove the access panel (on page

23

).

6.

Remove the air baffle (on page

25

).

7.

If installed, remove the PCI card from slot 9 ("

System board components

" on page

11

).

CAUTION:

Any attempt to remove an installed TPM from the system board breaks or disfigures

the TPM security rivet. Upon locating a broken or disfigured rivet on an installed TPM,

administrators should consider the system compromised and take appropriate measures to ensure

the integrity of the system data.

8.

Install the TPM board. Press down on the connector to seat the board ("

System board components

" on

page

11

).