beautypg.com

Population order, Installing a dimm – HP ProLiant ML350p Gen8 Server User Manual

Page 61

background image

Hardware options installation 61

Memory subsystem
channel

Population order

Slot number (Processor
2)

Slot number (Processor
1)

1

A

E

I

12

11

10

1

2

3

2

B

F

J

9

8

7

4

5

6

3

C

G

K

1

2

3

12

11

10

4

D
H

L

4
5

6

9
8

7

For the location of the slot numbers, see "DIMM slots (on page

12

)."

This multi-channel architecture provides enhanced performance in Advanced ECC mode. This architecture

also enables Lockstep and Online Spare Memory modes.
DIMM slots in this server are identified by number and by letter. Letters identify the population order. Slot

numbers indicate the DIMM slot ID for spare replacement.

Population order

For memory configurations with a single processor or multiple processors, populate the DIMM slots in the

following order:

LRDIMM: Sequentially in alphabetical order (A through L)

RDIMM: Sequentially in alphabetical order (A through L)

UDIMM: A through H, sequentially in alphabetical order. Do not populate DIMM slots I through L.

After installing the DIMMs, use RBSU to configure Advanced ECC, online spare, or lockstep memory support.

Installing a DIMM

CAUTION:

To avoid damage to the hard drives, memory, and other system components, the air

baffle, drive blanks, and access panel must be installed when the server is powered up.

1.

Do one of the following:

o

For tower models, open and remove the bezel ("

Remove the tower bezel

" on page

21

).

o

For rack models, if installed, remove the security bezel (on page

21

).

2.

Power down the server (on page

20

).

3.

Remove all power:

a.

Disconnect each power cord from the power source.

b.

Disconnect each power cord from the server.

4.

Do one of the following:

o

For tower models, place the server on a flat, level surface with the access panel facing up.