Population order, Installing a dimm – HP ProLiant ML350p Gen8 Server User Manual
Page 61
Hardware options installation 61
Memory subsystem
channel
Population order
Slot number (Processor
2)
Slot number (Processor
1)
1
A
E
I
12
11
10
1
2
3
2
B
F
J
9
8
7
4
5
6
3
C
G
K
1
2
3
12
11
10
4
D
H
L
4
5
6
9
8
7
For the location of the slot numbers, see "DIMM slots (on page
)."
This multi-channel architecture provides enhanced performance in Advanced ECC mode. This architecture
also enables Lockstep and Online Spare Memory modes.
DIMM slots in this server are identified by number and by letter. Letters identify the population order. Slot
numbers indicate the DIMM slot ID for spare replacement.
Population order
For memory configurations with a single processor or multiple processors, populate the DIMM slots in the
following order:
•
LRDIMM: Sequentially in alphabetical order (A through L)
•
RDIMM: Sequentially in alphabetical order (A through L)
•
UDIMM: A through H, sequentially in alphabetical order. Do not populate DIMM slots I through L.
After installing the DIMMs, use RBSU to configure Advanced ECC, online spare, or lockstep memory support.
Installing a DIMM
CAUTION:
To avoid damage to the hard drives, memory, and other system components, the air
baffle, drive blanks, and access panel must be installed when the server is powered up.
1.
Do one of the following:
o
For tower models, open and remove the bezel ("
" on page
o
For rack models, if installed, remove the security bezel (on page
2.
Power down the server (on page
3.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
4.
Do one of the following:
o
For tower models, place the server on a flat, level surface with the access panel facing up.