Level 4 – Allied Telesis AR44xS User Manual
Page 9

Features in 281-02
9
Version 281-02
C613-10482-00 REV B
Level 4
CR00013714
SSH
3
The router or switch’s SSH server occasionally disconnected an SSH client because
of a checksum error. This occurred because the server did not decrypt the SSH
session key correctly.
This issue has been resolved.
Y
-
Y
-
-
Y
-
-
-
-
CR00013757
Core
3
For AR750S-DP routers, the values of the fanAndPsPSUPresent MIB fields
displayed incorrectly. They indicated that a PSU was present when one was not
installed, and that it was not present when it was.
This issue has been resolved.
-
-
Y
-
-
-
-
-
-
-
CR
Module
Level
Description
AR40
0
AR7x
5
AR75
0S / AR770S
Rap
ier
i
AT
-8
8
0
0
AT
-8
6
0
0
A
T-
8
7
00XL
A
T-
8
9
48 /
x900-
48
AT
-9
9
0
0
AT
-9
8
0
0
CR00001359
Eth, Bridge,
Switch, LLDP,
IP Gateway
4
For all Ethernet-like interfaces, the router or switch now uses an ifType value of
ethernetCsmacd, instead of the deprecated value of iso88023Csmacd.
Y
-
Y
-
-
Y
-
-
-
-
CR00013174
Asyn, Core,
Log, Scripting,
Show
4
The console port’s autobaud mode was determined incorrectly during start-up.
This caused the router to unnecessarily reconfigure the console port for 9600
8N1 before printing any bootup messages.
This issue has been resolved.
-
-
Y
-
-
-
-
-
-
-
CR
Module
Level
Description
AR4
0
0
AR7
x
5
AR7
50S / AR770S
Ra
pi
er
i
AT
-8
8
0
0
AT
-8
6
0
0
A
T-
8
7
00XL
A
T-
8
9
48 / x900-
48
AT
-9
9
0
0
AT
-9
8
0
0