beautypg.com

Level 2 – Allied Telesis AR44xS User Manual

Page 15

background image

Features in 281-01

15

Version 281-02
C613-10482-00 REV B

Level 2

CR

Module

Level

Description

AR400

AR7x5

AR750S

/

AR77

0S

Rapi

er

i

A

T-

8800

A

T-

8600

A

T-

8700

XL

A

T-

8948

/

x90

0-

4

8

A

T-

9900

A

T-

9800

CR00009212

Bridge

2

The Bridge cannot be configured to bridge PPPoE packets from an Ethernet
interface that has also been configured as a PPPoE interface. Previously, such a
Bridge configuration would appear to succeed. However the Bridge would not
bridge PPPoE packets and the router would restart when the command reset
bridge
was entered.

This issue has been resolved. Note: if you want to bridge PPPoE packets, do not
also configure the router as a PPPoE endpoint (by using the command create
ppp=number
over=ethx-any).

Y

Y

Y

-

-

-

-

-

-

-

CR00009213

MSTP

2

Because of an MSTP issue, the switch did not always send a BPDU with an
agreement flag to its designated bridge, even if the switch was synchronised with
the latest spanning tree information from the designated bridge. This prevented
the designated port on the designated bridge from making a fast transition to
the forwarding state. The result was that the network could take up to two times
the “forward delay” time to fully converge.

This issue has been resolved.

-

-

-

Y

Y

Y

Y

Y

Y

-

CR00009826

IP Gateway

2

When a static ARP is deleted, the router or switch sends out an ARP request to
attempt to create a dynamic ARP for that IP address. Previously, the router or
switch did not process the ARP response correctly and therefore did not add the
ARP to its ARP table.

This issue has been resolved. When a static ARP is deleted, the router or switch
attempts to create a dynamic ARP for that IP address, and will successfully add it
to the ARP table if a device responds.

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

CR00010513

BGP,

IP Gateway

2

BGP did not update its route table when a blackhole route changed in IP.

This issue has been resolved.

Y

Y

Y

Y

Y

-

-

Y

Y

Y

This manual is related to the following products: