beautypg.com

Allied Telesis AR44xS User Manual

Page 19

background image

Features in 281-01

19

Version 281-02
C613-10482-00 REV B

CR00012846

ASYN, Log

2

The following issues occurred with sending log messages to an asynchronous
port:

The log messages output on an asynchronous port were corrupt.

When log messages were output to an asynchronous port, that port was
(correctly) locked. However, the port remained locked after the asynchronous
log output definition was destroyed, and after the log output's destination
was changed from asynchronous to something else.

It was possible for a user to change the log output destination to an
asynchronous port while the user was logged into the asynchronous port. This
resulted in the user losing access to the command line interface.

It was possible to create a log output definition with an asynchronous port as
the destination even when another user was logged into that asynchronous
port. This resulted in the other user losing access to the command line
interface.

If a user changed the log output destination to an asynchronous port and
specified invalid parameters in the command, an error message was displayed
but the new output destination was saved anyway.

The set command allowed a user to specify an asynchronous port as the
destination without specifying the asynchronous port number. The number
defaulted to asyn0, which may not have been the desired port.

These issues have been resolved.

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

CR00012855

Core

2

If the switch was rebooted at a time when there was a high level of packet traffic
between the switch ports and the switch CPU, then during the reboot process it
was possible for RAM test errors to occur.

This issue has been resolved.

-

-

-

-

-

-

-

Y

Y

-

CR

Module

Level

Description

AR4

0

0

AR7

x

5

AR7

50S / AR770S

Ra

pi

er

i

AT

-8

8

0

0

AT

-8

6

0

0

A

T-

8

7

00XL

A

T-

8

9

48 / x900-

48

AT

-9

9

0

0

AT

-9

8

0

0

This manual is related to the following products: