Level 3 – Allied Telesis AR44xS User Manual
Page 22
Features in 281-01
22
Version 281-02
C613-10482-00 REV B
Level 3
CR00013407
EPSR
2
The switch correctly accepted a changed ring flap time (the commands create or
set epsr ringflaptime). However, if the command create config was used to
save the configuration and the switch used that configuration after a reboot,
EPSR failed.
This issue has been resolved.
-
-
-
-
-
-
-
Y
Y
-
CR00013529
PIMv6
2
When the router or switch used PIM for multicast routing, and an IPv6 multicast
client joined a group, then left it, then attempted to rejoin it, sometimes the
attempt to rejoin was not successful.
This issue has been resolved.
Y
Y
Y
Y
Y
-
-
Y
Y
Y
CR
Module
Level
Description
AR40
0
AR7x
5
AR75
0S / AR770S
Rap
ier
i
AT
-8
8
0
0
AT
-8
6
0
0
A
T-
8
7
00XL
A
T-
8
9
48 /
x900-
48
AT
-9
9
0
0
AT
-9
8
0
0
CR00008766
TTY
3
Editing a text file that consisted of a very large number of lines (approaching or
exceeding 30,000 lines) caused the router or switch to reboot.
This issue has been resolved.
Y
-
Y
-
-
-
-
Y
Y
-
CR00011444
Asyn
3
If information was sent to a console (asyn) port that had no cable plugged into
it, excessive CPU usage occurred.
This issue has been resolved.
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
CR
Module
Level
Description
AR4
0
0
AR7
x
5
AR7
50S / AR770S
Ra
pi
er
i
AT
-8
8
0
0
AT
-8
6
0
0
A
T-
8
7
00XL
A
T-
8
9
48 / x900-
48
AT
-9
9
0
0
AT
-9
8
0
0