beautypg.com

Hp smart update manager return codes – HP ProLiant BL685c G5 Server Blade User Manual

Page 52

background image

Scripted deployment 52

hpsum /b BP000315.xml /f:bundle /softwareonly

Results: All the software components from the 7.80 PSP, which HP Smart Update Manager determined
needed to be installed, were installed. No firmware was installed.
Example 3:
This command line input deploys firmware:
hpsum /romonly
Results: All the firmware components, which HP Smart Update Manager determined needed to be
installed, were installed. No software was installed.
Example 4:
Either of the following command line inputs can deploy two software components:

hpsum /f:software cp008097.exe cp008257.exe

hpsum /c cp008097.exe /c cp008257.exe /f:software

Results: The two components were installed. No firmware or other software was installed.
Example 5:
Either of the following command line inputs can deploy the latest PSP, later versions of components in the
bundle, and firmware to three remote hosts and force all components to be installed:

hpsum /group "Management Servers" /current_credential /use_latest

/allow_update_to_bundle /allow_non_bundle_components /force:all

/override_existing_connection /continue_on_error ServerNotFound /silent

/logdir "Management_Server_Files"

hpsum /target "Management Server1" /target "Management Server2" /target

"Management Server3" /user administrator /passwd letmein /use_latest

/allow_update_to_bundle /allow_non_bundle_components /force:all

/override_existing_connection /continue_on_error ServerNotFound /silent

/logdir "Management_Server_Files"

Results: All the firmware components, software components from the 7.90 PSP, cp008097.exe, and

cp008257.exe were installed on Management Server1, Management Server2, and Management

Server3.

HP Smart Update Manager return codes

HP Smart Update Manager has consolidated return codes from Linux and Windows® components into a
new, enhanced return code mapping. These return codes determine the status of the component
installation. You can also use return codes in a script to control the execution of the script and determine
any required branching.
In Linux, the negative return codes are reported. These return codes are determined by subtracting the
negative value from 256.
To view the installation log file locations, see "Viewing the installation results (on page

30

)."

Return code

Value Linux Window

s

Text

SUCCESS_NO_REBOOT

0

0

0

The installation was successful.