beautypg.com

Connect gas supply – Bosch HDS7052U User Manual

Page 9

background image

9

Connect Gas Supply

Important note for LP users: The range is shipped
from the factory for use with natural gas. For use
with propane (LP) gas, your range must first be con-
verted using the LP conversion kit.
The gas connection is located below the back panel
of the range (page 7). It is accessible through the
warming drawer access panel or from the back of
the range. To reach access panel, remove warming
drawer.
Shut off main gas supply valve before disconnecting
the old range and leave it off until the new hook-up
has been completed. Don’t forget to relight the pi-
lot on other gas appliances when you turn the gas
back on.
The range can be installed using rigid pipe or a CSA
International-certified flexible metal appliance con-
nector. If using a flexible connector, always use a
new connector.
Apply pipe joint compound or Teflon** tape appropri-
ate for use with LP gas and Natural gas around all
male pipe threads to prevent leaks.
If not already present, install gas shut off valve in an
easily accessible location. Make sure all users know
where and how to shut off the gas supply to the
range.
NOTE: The installer should inform the consumer of
the location of the gas shutoff valve.

Flexible Connector Method

Gas Shut-
Off Valve

Flexible
Connector

Regulator

1. Install male ½" (12.7 mm) flare adaptor at the ½"

(12.7 mm) NPT internal thread of the range inlet.
Use a backup wrench on the elbow fitting to avoid
damage.

2. Install male ½" (12.7 mm) or ¾" (19 mm) flare

union adapter on the NPT internal thread of the
manual shutoff valve.

3. Connect flexible metal appliance connector.

,

CAUTION

Before you plug in an electrical cord, be sure all con-
trols are in the OFF position.
4. Make sure circuit breaker is off and then plug

range cord into electrical outlet.

5. Slide range into position ensuring that the left

back leg slides under the anti-tip bracket. Range
will sit ¾" (19 mm) away from back wall when
properly installed.

NOTE: Be careful not to crimp flexible connector!

8. Attach black wire, round washer, star washer and

nut IN THIS ORDER to right post.

Red

White

Black

9. Tighten all connections securely and replace ter-

minal block cover.

10. Properly secure strain relief (see previous page).

NOTE: DO NOT plug in range at this time. Proceed to