beautypg.com

Procedure, Caution – Bosch HDS7052U User Manual

Page 6

background image

6

General Information
Ranges are dual rated for use on either 120/240 VAC
or 120/208 VAC. See chart below for power ratings
and circuit breaker sizes based on the supply voltage
for each model.

MODEL: HDS

VOLTS A.C. HZ RATING KW CIRCUIT BREAKER

120/240

60

6.5

30 AMPS

120/208

60

4.8

30 AMPS

,

CAUTION

Make certain that gas shutoff valve and all burner con-
trols are in the OFF position before beginning.

Procedure

Prepare Electrical Connection

Installation of anti-tip bracket

1. Adjust height of range and level by rotating the ad-

justable leg supports on the bottom of the range,
using 1-4" (32 mm) wrench.

2. Locate bracket position as shown below.

3. Secure bracket with 2 screws to the floor or to

the wall. Depending on floor or wall material use
wood or anchorless concrete screws (included).
Concrete screws require a 3/16” masonry bit.
Screws should provide firm attachment into solid
wood or flooring. Do not attempt to anchor into
drywall.

3. Prepare Gas Supply Line and Electrical Outlet
The gas supply line and electrical outlet must be
located in the shaded area.

7 1/2"

4 1/2"

13 1/8 "

4"

3 7/8"

4 1/2"

3 1/2"

30"

Place Gas Supply

Line and Electrical

Outlet Here

7 1/2”

4 1/2”

13 1/8”

4”

3 7/8”

3 1/2”

4 1/2”

30”

4. Prepare Walls and Floor
Seal any holes in the walls or floor. Remove any ob-
structions (extra electrical or gas connections, etc.)
so that range will rest against wall properly.

*Instructions were determined using standard American cabinets. Standard

base cabinets measure 36" (91.4 cm) high x 24" (61 cm) deep . Cabinets

over the cooking surface and cabinets adjacent to those over the cooking

surface measure 13" (33 cm) deep from backwall. If nonstandard cabinets

are used, care should be taken to alter dimensions accordingly.

** 12 mm clearance from range sidewall to cabinet required in Canada.