Deleting a Motion Detection Window
To delete a window, simply select the motion detection window you wish to delete and press the
Delete button.
Reinstating the Factory Default Settings
In certain circumstances, it may be necessary to reinstate the Factory Default settings for your
AXIS 2120. This is performed by clicking the appropriate button in the Administration Tools, or
by pressing the Control Button. Follow the instructions below to reinstate the product factory
default settings using the Control button:
1. Switch off the AXIS 2120 by disconnecting the power cable.
2. Press and keep the Control Button pressed, and then reconnect the power supply cable.
3. Keep the Control Button pressed until the Status Indicator displays yellow (note that this may
take up to 15 seconds), then release the button. When the Status Indicator displays green
(which can take up to 1 minute) the AXIS 2120 will then have been reset to the original
factory default settings.
Notes:
•Reinstating the factory default settings will cause all parameters (including the IP address) to be
reset.
•Refer to Installing Your Camera on a Network, on page 12, or Alternative Methods of Assigning the
IP Address, on page 15, for information on how to set the IP address in the product.