beautypg.com

Takagi T-M32 User Manual

Page 43

background image

- 43 -

Dual-purpose hot water heating (Domestic and Space Heating):

Priority Control Devices such as a flow switch, an Aquastat or other electronic controller can be used to
prioritize the domestic water system over the heating system.

Warning: Follow all local codes, or in the absence of local codes, follow the most recent edition of the
National Standard Code, ANSI Z21. 10.3.

Warning: This illustration is a concept design only. The reference to the 1/8

th

hole in check is only for

the State of Massachusetts. There are a wide variety of variations to the application of controls and
equipment presented. Designers must add all necessary safety and auxiliary equipment to conform to
code requirements and design practice. For more details, contact the Takagi Technical Department at
(888) 882-5244

* Size the pump to provide at about 2 GPM through the system at 15 Ft of Head plus applications
and piping head losses. 2 GPM will allow the system to operate at its optimal performance.
* If the application requires a higher re-circulating flow rate, make sure that the re-circulating flow
rate is no greater than 4
GPM. If the flow rate is too high, the system could be damaged by
erosion.

Takagi

P

T

An approved Pressure Only

Relief Valve, Tie to Location
approved by Local Codes and
Must Meet BTU Rating of Takagi
Model Used

Unions

4" Gas Exhaust Vent (Discharge

Must Comply with Local and
State Codes). Can Not Be
Common Vented with Other

Appliances

Atmospheric
Vacuum Breaker

Pump (Must Be Sized Properly

With Each Application). Pump
Shall Run 60 Seconds Every 6

Hours

Pressure

Gauge

Apply Correct
Thermal

Expansion

Tank-Size Per
Application

Tempered
Water To

House

Cold Inlet

Shut-Off
Valve

Check Valve Will
Have 1/8" Hole in
Check, As Per
Mass. Code

Thermometer

Thermostatic Mixing Valve

Shut-Off
Valves

Check Valve

Hot

Water
Outlet

Cold
Water
Inlet

T-Handle Gas
Shut-Off Valve

**Maximum allowable distance of
50-Ft. from water heater and
heating panel

Heating Coil

(used with air-handler)

Diagramatic Layout of Radiant Heating and

Domestic Water Heater Per Mass. Code

Thermometer

Check

Valves

Gas
Inlet

Drain
Plug

Water

Filter

120 VAC Switch or Outlet