Water heater, Remote controller: tm-re30 (optional), Easy link system – Takagi T-M32 User Manual
Page 37
- 37 -
~ WATER HEATER ~
PROBLEM POSSIBLE
SOLUTIONS
Unit does not ignite when water goes
through the unit.
• Is the flow rate over 0.5 GPM? (p. 31)
• Check for the filter on cold water inlet. (p. 35)
• Check for reverse connection and cross connection.
• If you use the remote controller, is the power button
turned on? (p. 31)
The fan motor is still spinning after
operation has stopped.
• This is normal. After operation has stopped, the fan
motor keeps running for 35 seconds in order to re-
ignite quickly, as well as push all exhaust gas out of
the flue.
Abnormal sounds come from the unit.
• Contact TAKAGI.
~ REMOTE CONTROLLER: TM-RE30 (OPTIONAL) ~
PROBLEM POSSIBLE
SOLUTIONS
Remote controller does not display
anything when the power button is
turned on.
Press the ON/OFF button.
If the lamp lights up ⇒
• This is normal. When the unit has not operated for
five minutes or more, the display turns off to
converse energy.
If the lamp does not light ⇒
• Make sure the unit has power supply.
• Make sure the connection to the unit is correct.(p. 20)
An ERROR code is displayed.
• Please see the p. 38.
~ EASY LINK SYSTEM ~
PROBLEM POSSIBLE
SOLUTIONS
How are the unit numbers assigned?
• For an Easy-Link system, other than the Master Unit
(which is always labeled #1), all the other units (the
Slave units) are numbered randomly.
• To check which numbers are assigned to which
units, push the button on the computer board of a
unit as shown below. The unit number will be
displayed on the 7-Seg LED.
Button to check
unit numbers
7-Seg LED