- 37 -

~ WATER HEATER ~

PROBLEM POSSIBLE

SOLUTIONS

Unit does not ignite when water goes
through the unit.

• Is the flow rate over 0.5 GPM? (p. 31)
• Check for the filter on cold water inlet. (p. 35)
• Check for reverse connection and cross connection.
• If you use the remote controller, is the power button

turned on? (p. 31)

The fan motor is still spinning after
operation has stopped.

• This is normal. After operation has stopped, the fan

motor keeps running for 35 seconds in order to re-
ignite quickly, as well as push all exhaust gas out of
the flue.

Abnormal sounds come from the unit.

• Contact TAKAGI.

~ REMOTE CONTROLLER: TM-RE30 (OPTIONAL) ~

PROBLEM POSSIBLE

SOLUTIONS

Remote controller does not display
anything when the power button is
turned on.

Press the ON/OFF button.

If the lamp lights up ⇒
• This is normal. When the unit has not operated for

five minutes or more, the display turns off to
converse energy.

If the lamp does not light ⇒
• Make sure the unit has power supply.
• Make sure the connection to the unit is correct.(p. 20)

An ERROR code is displayed.

• Please see the p. 38.

~ EASY LINK SYSTEM ~

PROBLEM POSSIBLE

SOLUTIONS

How are the unit numbers assigned?

• For an Easy-Link system, other than the Master Unit

(which is always labeled #1), all the other units (the
Slave units) are numbered randomly.

• To check which numbers are assigned to which

units, push the button on the computer board of a
unit as shown below. The unit number will be
displayed on the 7-Seg LED.







Button to check
unit numbers

7-Seg LED