Normal operation, Warning ning, Without remote controller – Takagi T-M32 User Manual
Page 31
- 31 -
(unit:°F)
Temperatures available under the High Temperature Mode
NORMAL OPERATION
• Flow rate to activate the T-M32:
0.5 gallon per minute
• Flow rate to keep the T-M32 running : 0.4 gallon per minute
1. NORMAL OPERATION
WITHOUT REMOTE CONTROLLER
1. Open a hot water tap.
2. Mix cold water with the hot to get
the correct temperature water.
3. Close the hot water tap.
2. NORMAL OPERATION
WITH REMOTE CONTROLLER INSTALLED: TM-RE30 (Optional)
1. Press the power ON/OFF button. 2. Set temperature. (Example 110°F)
WARNING NING
Hot Water temperatures over 125
°F can cause severe burns
instantly or death from scalding.
•
The outlet hot water temperature of the Mobius T-M32 water
heater is factory set at 120
°F.
•
Feel the water temperature before bathing or showering.
100
105
110
115
120
125
130
135
140
145
150
155
160
165
170
175
110
115
120
125
130
135
140
145
150
155
160
165
170
175
180
185
The temperature and the
time will be displayed on
the remote controller.
Temperatures available under the Default Mode
3. Open a hot water tap.
Mix cold water with the hot if you need.
4. Close the hot water tap.
DO NOT set to 185 °F if you use your T-M32 in recirculation system. Refer to p.34
*If the TM-RE10 is used, refer to the TM-RE10 Installation Manual included with the remote.
Lamp is ON
Lamp is ON
Lamp is OFF
Lamp is OFF
When ON,
green LED is lit.