beautypg.com

Troubleshooting – error codes – Takagi T-M32 User Manual

Page 38

background image

- 38 -

TROUBLESHOOTING – ERROR CODES

All Takagi units are self diagnostic for safety and convenience when trouble shooting.

If there is a problem with the installation or the unit, it will display a numerical error code on the
TM-RE30 (if installed) or on the 7-Seg LED of the central computer board and section computer
board to communicate the source of the problem.

Consult the following chart for the cause of each error code.





Single Unit

The 7-Seg LED displays the 3-digit error codes one
digit at a time. The TM-RE30 (if installed) displays
the whole 3-digit error code at once.


Example:
If your unit has the “321” error code (inlet thermistor),

The 7-Seg LED, will flash the 3-digit error code one
digit at a time. The 7-Seg LED will display “3”...
“2”... “1”, and then repeat the 3 digits.

The remote controller, however, will display “321”
on its screen, in its entirety.




Easy Link

The 7-Seg LED on the Master unit displays a 5-digit
number to signify which unit in the Easy Link system
has the error, and what the error code is. The 7-Seg
LED displays the number one digit at a time.

The TM-RE30 (if installed) displays a 3-digit number
which also signifies which unit has the error, and what
the error code is.

The unit that has the error in an Easy Link system will
display the error code on its 7-Seg LED in exactly the
same way as if it were only a Single Unit.


Example:
If Unit #2 has the “321” error code (inlet thermistor),

The 7-Seg LED on the Master unit will display “3”...
“2”… “1”… “0”… “2”, displaying only one digit at a
time. The first 3 numbers indicate the error code.
The last two numbers indicate that Unit #2 has the
error.

The remote controller, however, will display “232” on
its screen in its entirety. The first “2” indicates that
Unit #2 has the error. The “32” indicates the first two
digits of the “321” error code.

The 7-Seg LED on Unit #2 will display “3”…. “2”…. “1”,
just like in the Single Unit example.

Error

Code

Malfunction description

Error

Code

Malfunction
description

Error

Code

Malfunction
description

031

Dipswitch Setting fault

391

Air-fuel Ratio Rod Failure

661

Water Control Valve Fault

(Bypass function)

101

Warning for 991 Error Code

441

Flow Sensor Failure

701

Computer board Fault

111

Ignition Failure

510

Abnormal Main Gas

Valve

721

False Flame Detection

121

Flame blows out

551

Abnormal Gas Solenoid

Valve

741

Miscommunication between

T-M32 and TM-RE30

311

Output Thermistor Failure

611

Fan Motor Fault

761

Miscommunication in Easy

link OR Multi-unit system

321

Inlet Thermistor Failure

631

Abnormal External Pump

991

Abnormal burning

331

Mixing Thermistor Failure

651

Water Control Valve Fault

(Flow Adjustment

function)

TM-RE30 (Optional)

7-Seg LED

Remote