5
Pressure
Ranges
Standard
Code “00”
High Over
pressure-
Option
Code “01”
Full Scale Range
(PSI)
Burst
Pressure*
(PSI)
Proof
Pressure**
(PSI)
High Proof
Pressure
(PSI)
15
25
50
100
150
200
300
500
750
1000
3000
3000
8000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
30 (2x)
50 (2x)
100 (2x)
200 (2x)
300 (2x)
400 (2x)
600 (2x)
800 (1.5x)
1200 (1.5x)
1500 (1.5x)
150 (10x)
250 (10x)
500 (10x)
1000 (10x)
1200 (8x)
1200 (6x)
1500 (5x)
2000 (4x)
2250 (3x)
3000 (3x)
* Burst Pressure: the maximum pressure that may be applied to the positive pressure port without rupturing the sensing element.
** Proof Pressure: The maximum recoverable pressure that may be applied without changing performance beyond specification: ±0.5% Zero Shift,
Typical
Performance Data
See also other documents in the category Setra System Sensors:
- Model 204 (4 pages)
- Model 209 (4 pages)
- Model 227 (8 pages)
- 264 (4 pages)
- 269 (4 pages)
- Model 280E (4 pages)
- Model 370 (48 pages)
- Model 526 (7 pages)
- Model 540 (9 pages)
- Model 595 (8 pages)
- Model 869 (28 pages)
- Model 321 (4 pages)
- Model SRH (12 pages)
- Model Datum 2000 (31 pages)
- Model 217 (8 pages)
- Model 230 (12 pages)
- Model 242901-06 (1 page)
- Model 265 (4 pages)
- Model 270 (5 pages)
- Model 299 (4 pages)
- Model 470 (35 pages)
- Model 524 (6 pages)
- Model 546 (8 pages)
- Model 730 (16 pages)
- GCT-225 (8 pages)
- Model 141 (4 pages)
- Model 205-2 (4 pages)
- Model 223 (8 pages)
- Model 231 (12 pages)
- Model 256 (8 pages)
- Model 276 (2 pages)
- Model 3100 (8 pages)
- Model 516 (6 pages)
- Model 550 (9 pages)
- Model 760 (18 pages)
- Model LD330 (4 pages)
- Model SRMD (8 pages)
- Model 201 (4 pages)
- Setra Model 206 (4 pages)
- Model 224 (8 pages)
- Model 231RS (16 pages)
- 260 (2 pages)
- 267MR (14 pages)
- Model 278 (2 pages)