beautypg.com

Mpm, apm, ppm, & lti series modbus, Register tables serial communication – Dwyer PPM User Manual

Page 8

background image

MPM, APM, PPM, & LTI Series Modbus

®

Register Tables

Serial Communication

Page 8

Register

1

Name Access

Limits or

Range

2

Units

Data

Type

3

Function

Code(s)

Comments

Number Address

(hex)

40072 – 40073

71 – 72

(0047 – 0048)

Modbus Big

Display value

Read Write

-99999 to

+999999

User defined

Long Hi

Long Lo

03, 04,

06, 16

Represents the Modbus Big display value excluding the decimal
point. Register 40088 contains the decimal point.
Set Register 40070 = 0, Register 40117 = 18

40074 – 40075

73 – 74

(0049 – 004A)

Modbus Little
Display value

Read Write

-99999 to

+999999

User defined

Long Hi

Long Lo

03, 04,

06, 16

Represents the Modbus Little display value excluding the
decimal point. Register 40089 contains the decimal point.
Register 40071 = 0, Register 40118 = 18

40076

75

(004B)

Modbus Big

Display MSD

value

Read Write

Not applicable

None

Byte

03, 04,

06, 16

Represents the Modbus Big Display MSD (Most Significant
Digit) value. The hex value represents the allowable ASCII
character, see Table 7.
Register 40117 = 18
Register 40070 = 1 for registers 40076-81.
Register 40088 contains the decimal point.

40077

76

(004C)

Modbus Big

Display MSD-1

value

Read Write

Not applicable

None

Byte

03, 04,

06, 16

Represents the Modbus Big Display MSD-1 value. The hex
value represents the allowable ASCII character.

40078

77

(004D)

Modbus Big

Display MSD-2

value

Read Write

Not applicable

None

Byte

03, 04,

06, 16

Represents the Modbus Big Display MSD-2 value. The hex
value represents the allowable ASCII character.

40079

78

(004E)

Modbus Big

Display MSD-3

value

Read Write

Not applicable

None

Byte

03, 04,

06, 16

Represents the Modbus Big Display MSD-3 value. The hex
value represents the allowable ASCII character.

40080

79

(004F)

Modbus Big

Display MSD-4

value

Read Write

Not applicable

None

Byte

03, 04,

06, 16

Represents the Modbus Big Display MSD-4 value. The hex
value represents the allowable ASCII character.

40081

80

(0050)

Modbus Big

Display MSD-5

(LSD) value

Read Write

Not applicable

None

Byte

03, 04,

06, 16

Represents the Modbus Big Display MSD-5 (which is the LSD)
value. The hex value represents the allowable ASCII character.

40082

81

(0051)

Modbus Little

Display MSD

value

Read Write

Not applicable

None

Byte

03, 04,

06, 16

Represents the Modbus Little Display MSD (Most Significant
Digit) value. The hex value represents the allowable ASCII
character, see Table 7.
Register 40118 = 18
Register 40071 = 1 for registers 40082-87.
Register 40089 contains the decimal point.

40083

82

(0052)

Modbus Little

Display MSD-1

value

Read Write

Not applicable

None

Byte

03, 04,

06, 16

Represents the Modbus Little Display MSD-1 value. The hex
value represents the allowable ASCII character.

40084

83

(0053)

Modbus Little

Display MSD-2

value

Read Write

Not applicable

None

Byte

03, 04,

06, 16

Represents the Modbus Little Display MSD-2 value. The hex
value represents the allowable ASCII character.

This manual is related to the following products: