Mpm, apm, ppm, & lti series modbus, Register tables serial communication – Dwyer PPM User Manual
Page 34

MPM, APM, PPM, & LTI Series Modbus
®
Register Tables
Serial Communication
Page 34
Table 3.
User Programmable Settings
Digital Inputs & Function Keys Setting (40152 – 40162)
Digital Outputs Settings (40163 – 40169)
Integer
Function
Key, DI
Reg. No.
Integer
Function
0 Disable
Function
F1
152
0
Disable
Function
1 Menu
Key F2
153
1
Alarms
Acknowledged
2 Right Arrow Key
F3
154
2
End of Batch
3 Up Arrow Key DI-1
155
3
Batch
Counter
Reset
4 Enter
Key DI-2
156
4
Total
Reset
5 Acknowledge Alarms
DI-3
157
5
Grand Total Reset
6
Select Reset Menu
DI-4
158
6
Maximum Value Reset
7
Select Reset Batch Counter
DI-5
159
7
Minimum Value Reset
8
Select Reset Total
DI-6
160
8
Maximum/Minimum Value Reset
9
Select Reset Grand Total
DI-7
161
9
Reserved
10
Select Reset Maximum Value
DI-8
162
10
Reserved
11
Select Reset Minimum Value
11
Alarm 1 Active
12
Select Reset Max & Min Values
12
Alarm 2 Active
13 Reserved
13
Alarm 3 Active
14 Reserved
14
Alarm 4 Active
15 Select
Relay Menu
15
Alarm 5 Active
16
Select Set Point 1 Programming
16
Alarm 6 Active
17
Select Set Point 2 Programming
17
Alarm 7 Active
18
Select Set Point 3 Programming
18
Alarm 8 Active
19
Select Set Point 4 Programming
19
Start Batch
Selected
20
Select Set Point 5 Programming
20
Stop Batch
Selected
21
Select Set Point 6 Programming
22
Select Set Point 7 Programming
DO
Reg. No.
23
Select Set Point 8 Programming
DO-1
163
24 Select
Start Batch
DO-2
164
25 Select
Stop Batch
DO-3
165
26 Reserved
DO-4
166
27 Select
Relay
Disable
DO-5
167
28 Select
Relay
Enable
DO-6
168
29 Select
Relay
Output Hold
DO-7
169
30 Reserved
DO-8
170
31 Select
Display Menu
32 Select
Big Display Menu
33
Select Maximum Value on Big Display
34
Select Minimum Value on Big Display
35
Select Maximum/Minimum Value on Big Display
36
Select Little Display Menu
37
Select Maximum Value on Little Display
Note: Some of the functions listed are dependent on
model being used. For example: the batch
functions are only available with the batch
controller model.
38
Select Minimum Value on Little Display
39
Select Maximum/Minimum Value on Little Display
40 Force
ON
Relay #1 (Relay 1 Action must be set to Off)
41 Force
ON
Relay #2 (Relay 2 Action must be set to Off)
42 Force
ON
Relay #3 (Relay 3 Action must be set to Off)
43 Force
ON
Relay #4 (Relay 4 Action must be set to Off)
44
Select Grand Total Value on Little Display (Batch)
45
Select Batch Count Value on Little Display (Batch)