Mpm, apm, ppm, & lti series modbus, Register tables serial communication – Dwyer PPM User Manual
Page 29

MPM, APM, PPM, & LTI Series Modbus
®
Register Tables
Serial Communication
Page 29
Register
1
Name Access
Limits or
Range
2
Units
Data
Type
3
Function
Code(s)
Comments
Number Address
(hex)
44023 – 44024
4022 – 4023
(FB6 – FB7)
Scale PV2 mA
Input 4
Read Write -99.999 to 99.999
mA
Floating point
03, 04,
06, 16
44025 – 44026
4024 – 4025
(FB8 – FB9)
Scale PV2 mA
Input 5
Read Write -99.999 to 99.999
mA
Floating point
03, 04,
06, 16
44027 – 44028
4026 – 4027
(FBA – FBB)
Scale PV2 mA
Input 6
Read Write -99.999 to 99.999
mA
Floating point
03, 04,
06, 16
44029 – 44030
4028 – 4029
(FBC – FBD)
Scale PV2 mA
Input 7
Read Write -99.999 to 99.999
mA
Floating point
03, 04,
06, 16
44031 – 44032
4030 – 4031
(FBE – FBF)
Scale PV2 mA
Input 8
Read Write -99.999 to 99.999
mA
Floating point
03, 04,
06, 16
44129
4128
(1020)
Remote Scale
PV2 mA Flag
Write Only
0xFF00 to
execute remote
scaling.
None
Unsigned
integer
06, 16
Used to remote scale the PV2 mA input. Caution! See Note 5.
45001 – 45002
5000 – 5001
(1388 – 1389)
Scale PV2 Volts
Display 1
Read Write -99999 to 999999
User defined
Floating point
03, 04,
06, 16
After all the Display and Input values have been sent, write
0xFF00 to register 45129.
45003 – 45004
5002 – 5003
(138A – 138B)
Scale PV2 Volts
Display 2
Read Write -99999 to 999999
User defined
Floating point
03, 04,
06, 16
45005 – 45006
5004 – 5005
(138C – 138D)
Scale PV2 Volts
Display 3
Read Write -99999 to 999999
User defined
Floating point
03, 04,
06, 16
45007 – 45008
5006 – 5007
(138E – 138F)
Scale PV2 Volts
Display 4
Read Write -99999 to 999999
User defined
Floating point
03, 04,
06, 16
45009 – 45010
5008 – 5009
(1390 – 1391)
Scale PV2 Volts
Display 5
Read Write -99999 to 999999
User defined
Floating point
03, 04,
06, 16
45011 – 45012
5010 – 5011
(1392 – 1393)
Scale PV2 Volts
Display 6
Read Write -99999 to 999999
User defined
Floating point
03, 04,
06, 16
45013 – 45014
5012 – 5013
(1394 – 1395)
Scale PV2 Volts
Display 7
Read Write -99999 to 999999
User defined
Floating point
03, 04,
06, 16
45015 – 45016
5014 – 5015
(1396 – 1397)
Scale PV2 Volts
Display 8
Read Write -99999 to 999999
User defined
Floating point
03, 04,
06, 16
45017 – 45018
5016 – 5017
(1398 – 1399)
Scale PV2 Volts
Input 1
Read Write -99.999 to 99.999
Volt
Floating point
03, 04,
06, 16
45019 – 45020
5018 – 5019
(139A – 139B)
Scale PV2 Volts
Input 2
Read Write -99.999 to 99.999
Volt
Floating point
03, 04,
06, 16
45021 – 45022
5020 – 5021
(139C – 139D)
Scale PV2 Volts
Input 3
Read Write -99.999 to 99.999
Volt
Floating point
03, 04,
06, 16
45023 – 45024
5022 – 5023
(139E – 139F)
Scale PV2 Volts
Input 4
Read Write -99.999 to 99.999
Volt
Floating point
03, 04,
06, 16