beautypg.com

Installation – Blue Angel Pumps 63042-BLA1 User Manual

Page 2

background image

2

Operating Instructions

2 HP Grinder Pumps

12. Provide a means of pressure relief

for pumps whose discharge line can
be shutoff or obstructed.

13. Do not install the pump in any

location classified as hazardous by
National Electric Code, ANSI/NFPA
70-1984.

14. Secure the pump in its operating

position so it cannot tip over, fall or
slide. Install this pump in the vertical
position only.

15. Make sure lifting handles are securely

fastened each time before lifting. Do
not operate pump without safety
devices in place. Always replace safety
devices that have been removed
during service or repair. DO NOT LIFT
PUMP BY POWER CORD.

16. Do not run the pump dry. Dry

running can overheat the pump and
will void the warranty.

17. Personal Safety:

a. Wear safety glasses at all times

when working with pumps.
This pump is designed to
handle materials that could
cause illness or disease through
direct exposure. Wear and
use protective clothing when
working on the pump or piping.

b. Do not wear loose clothing that

may become entangled in the
impeller or other moving parts.

c. Keep clear of suction and

discharge openings. DO NOT
insert fingers in the pump with
power connected.

d. Keep work are clean,

uncluttered and properly
lighted: replace all unused tools
and equipment.

e. Keep visitors a safe distance

from the work area. Make
workshop childproof with
padlocks, master switches, and
by removing starter keys.

18. A qualified electrician should

perform all wiring of this pump.
When wiring an electrically driven
pump such as this, follow all
electrical and safety codes, as well
as the most recent National Electric
Code (NEC) and the Occupational
Safety and Health Act (OSHA).

Risk of Electric Shock!

Never connect the

green (or green and yellow) wire to a
live terminal!

This unit is not

designed for

application involving salt water or brine.
Use with salt water or brine will void
warranty.

Installation

This pump may be installed on a guide-
rail lift-out system for ease of inspection
and service. Guide-rails allow removal
of the pump without disturbing the
piping and eliminates the need to enter
the basin. If installed with a guide-rail
system, place the pump opposite the
influent opening to prevent stagnant
areas where solids can settle.
Install the pump on a hard, level surface.
Never place the pump directly on earth,
clay or gravel surfaces. The basin must be
at least 18” in diameter and 30” deep.
The discharge pipe must not be smaller
than the pump discharge.
The motor is provided with a thermal
overload switch (Single Phase Pump
Motors Only). If the motor overloads
or overheats for any reason, the switch
opens, stopping the motor. As soon as the
motor cools to normal temperature, the
switch automatically closes and restarts the
motor. on 3-Phase pumps, the installer
must provide the Motor Protection. In
accordance with the National Electric
code, all 3-phase pumps must be
installed with magnetic starters having
3 leg overload protection. For duplex
installations, both pump motors must
have separate overload protection.

Hazardous voltage.

Can shock, burn, start

a fire or kill. When installing, operating or
servicing this pump, follow electrical safety
instructions below. Only trained service
personnel should install or service this pump.

1. Do not splice the power cord.
2. Do not handle or service this pump

while it is connected to the power

supply.

3. Do not operate the pump unless it is

properly grounded. Connect the pump

according to all applicable codes.

4. Incorrect voltage can cause a fire

or seriously damage the motor and
voids the warranty. Make sure that
the frequency and voltage shown
on the nameplate corresponds to
the frequency and voltage of the
electrical supply.

5. Connect the pump to its own

circuit with nothing else on the
circuit. See Chart 1 for pump motor
specifications. See Figure 2 for wiring
diagram. Use a Control Panel sized
to match the pump. Refer to Control
Panel installation instructions for
wiring connections information.

6. The pump rotation must be

clockwise as viewed from the top of
the pump. If a three-phase unit runs
backwards, interchange two of the
three power supply wires to reverse
the motor’s direction of rotation.

7. Install the pump in accordance with

all electrical codes that apply. Install
a fused disconnect switch or circuit
breaker in accordance with local
codes.

Risk of electrical

shock. Pumps are

supplied with a grounding conductor on the
power cord. The grounding conductor is the
GREEN lead. To reduce the risk of electric
shock, be certain the ground conductor
is connected in the control box to the
grounding bar, which in connected to a
good suitable ground. The pump is not safe
to operate unless it is properly grounded.

Model Number

Motor

HP

Voltage

Frequency

Hz

Phase

Motor Full

load Amps

BAGP1-115

2

115

60

1

15.0

BAGP1-2021

2

230

60

1

14.5

BADSGP1-115

2

115

60

1

20.0

BARDSGP1-2021

2

230

60

1

14.5

BADSGP1-2001

2

200/208

60

1

16.9

BARDSGP1-2023

2

230

60

3

8.8

BAHGP2-2021

2

230

60

1

24.0

BAHGP2-2021C

2

230

60

1

24.0

BAHGP2-2021E1

2

230

60

1

14.8

BAHGP2-2023

2

230

60

3

12.2

chart 1 - Motor specifications

www.waynewatersystems.com