Chillers ultima ™ remote air cooled, General specification – Airedale Ultima Remote Air Cooled 75kW - 450kW User Manual
Page 21
![background image](/manuals/370946/21/background.png)
Chillers
ULTIMA
™ REMOTE AIR COOLED
Chillers
21
Technical Manual : Part No 6259485 V1.6.0_07_2014
General Specification
MECHANICAL DATA
URAC200
URAC225
URAC240
URAC250
URAC270
Duty
– Cooling
Cooling Only
(1)
kW
209.2
236.3
248.2
289.5
289.5
Nominal Input
(1)
kW
54.9
62.5
70.1
80.7
80.7
EER
(2)
3.8
3.7
3.5
3.7
3.6
Capacity Steps
%
0-25-50-75-100
0-20-30-50-70-80-100 0-17-33-50-67-83-100
0-25-50-75-100
0-19-33-52-67-86-100
Dimensions - H x L x W
(5)
mm
1850 x 2000 x 760
1900 x 3200 x 900 1850 x 2000 x 760 1900 x 3200 x 900
Weight
Machine - D
kg
1365
1425
1210
1495
1500
- DQ
kg
1405
1465
1280
1530
1570
- DSQ
kg
1440
1500
1300
1565
1590
Operating - D
kg
1380
1450
1230
1520
1530
- DQ
kg
1420
1490
1300
1555
1600
- DSQ
kg
1455
1525
1320
1590
1620
Construction - Material / Colour
Plain Galvanised Steel Base with Galvanised Sheet Steel, Epoxy Baked Powder Paint
Superstructure
– Light Grey (RAL 7035)
Evaporator
Brazed Plate
Insulation
Class 0
Water Volume
l
14.6
22.1
21.6
24.8
26.1
Total Max. Water Flow
l/s
16.8
19.0
17.2
21.3
20.1
Compressor
Tandem Scroll - Hermetic
Trio Scroll
–
Hermetic
Tandem Scroll -
Hermetic
Trio Scroll
–
Hermetic
Quantity
4
4
6
4
6
Oil Charge Volume (Total)
l
4.7 + 4.7 + 4.7 +
4.7
6.3 + 4.7 + 6.3 +
4.7
6 x 3.4
6.3 + 6.3 + 6.3 +
6.3
4.7+4.7+4.7+3.4
+3.4+3.4
Oil Type
Polyol Ester
Refrigeration
Dual Circuit
Refrigerant Control
Electronic Expansion Valve
Refrigerant Type
R407C
Holding Charge
Dry Nitrogen
Connections - Evaporator
Suits
“Victaulic” type Coupling & Pipe Assembly
Water Inlet / Outlet
mm / (in)
80 (3
”)
80 (3
”)
80 (3
”)
80 (3
”)
80 (3
”)
Connections
– Condenser – CCT1
Discharge Line (Brazed)
in
1 5/8
1 5/8
1 5/8
1 5/8
1 5/8
Liquid Line (Brazed)
in
1 3/8
1 3/8
1 3/8
1 3/8
1 3/8
Connections
– Condenser – CCT2
Discharge Line (Brazed)
in
1 5/8
1 5/8
1 5/8
1 5/8
1 5/8
Liquid Line (Brazed)
in
1 3/8
1 3/8
1 3/8
1 3/8
1 3/8
Water System - Evaporator
Min. System Water Volume (3)
l
991
890
763
1235
995
Max. System Press
Bar
10
10
10
10
10
(1)
Nominal Cooling Duties based on 12/7°C water temperature and 45°C dew point, where output is the chilled water duty and
input is the compressor input power.
All performance data is supplied in accordance with BS EN 14511-1:2013
(2)
EER is the Cooling Duty
compressor input power.
(3)
For minimum system volume refer to
Minimum System Water Volume Calculations