KROHNE DW 181-182-183-184 EN User Manual
Page 8
8
Installation and operating instructions DW 181 - 184
Type code
Refer to the standard device label, item 2 on the previous page.
DW . . . / . / . . . . / . . / . / . . . / . . / . .
1 2 3 4 5 6 7 8
Type code element
Code
Code definition
1 Type series
181
182
183
184
For horizontal or vertical pipes, screw
connection G¾…G2, measuring system C or
E*
For horizontal or vertical pipes, flange
connection DN15…65 and ½”…2”-150 lbs,
measuring system C or E*
For horizontal or vertical pipes, flange
connections DN65…200 and 3”…8”-150 lbs,
measuring system P*
For horizontal pipes (DN ≥250 or 10”, mounting
flange DN150 PN16 or 6”-150 lbs, measuring
system P*
2 Measuring system
C
E
P
Measuring disc in tapered tube
Nozzle with baffle
Baffle in constant diameter pipe
3 Code number
011 - 204
See section 7.1: Flow range table for the
characteristics of each code number.
4 Material of construction
- see also section 7.2
B
RR
R
N
Bronze
Stainless steel (SS) 316 L
SS 316L measuring tube, steel connection
Steel
5 Indicator system
G
A
Linear scale marks
Dial with flow units
6 Limit switches
K1
K2
KV1
KV2
1 NC or 1 NO switch**
1 NC and 1 NO switch**
Amplifier relay: 1 change-over switch**
Amplifier relay: 2 change-over switches**
7 Application field
N
Ex d
Ex ia
Normal locations
Hazardous locations
Intrinsically-safe applications
8 Connection
G ¾…G2
DN15…200
(½”…8”)
Pipe thread
Flange connection
* Refer to section 9.1
** Bistable.
NO is a “normally open” switch during operation (closed switch when flow is decreasing)
NC is a “normally closed” switch during operation (closed switch when flow is increasing).