beautypg.com

KROHNE DW 181-182-183-184 EN User Manual

Page 8

background image

8

Installation and operating instructions DW 181 - 184

Type code


Refer to the standard device label, item 2 on the previous page.

DW . . . / . / . . . . / . . / . / . . . / . . / . .
1 2 3 4 5 6 7 8

Type code element

Code

Code definition

1 Type series

181


182


183


184

For horizontal or vertical pipes, screw
connection G¾…G2, measuring system C or
E*
For horizontal or vertical pipes, flange
connection DN15…65 and ½”…2”-150 lbs,
measuring system C or E*
For horizontal or vertical pipes, flange
connections DN65…200 and 3”…8”-150 lbs,
measuring system P*
For horizontal pipes (DN ≥250 or 10”, mounting
flange DN150 PN16 or 6”-150 lbs, measuring
system P*

2 Measuring system

C
E
P

Measuring disc in tapered tube
Nozzle with baffle
Baffle in constant diameter pipe

3 Code number

011 - 204

See section 7.1: Flow range table for the
characteristics of each code number.

4 Material of construction
- see also section 7.2

B
RR
R
N

Bronze
Stainless steel (SS) 316 L
SS 316L measuring tube, steel connection
Steel

5 Indicator system

G
A

Linear scale marks
Dial with flow units

6 Limit switches

K1
K2
KV1
KV2

1 NC or 1 NO switch**
1 NC and 1 NO switch**
Amplifier relay: 1 change-over switch**
Amplifier relay: 2 change-over switches**

7 Application field

N
Ex d
Ex ia

Normal locations
Hazardous locations
Intrinsically-safe applications

8 Connection

G ¾…G2
DN15…200
(½”…8”)

Pipe thread
Flange connection


* Refer to section 9.1
** Bistable.
NO is a “normally open” switch during operation (closed switch when flow is decreasing)
NC is a “normally closed” switch during operation (closed switch when flow is increasing).