beautypg.com

KROHNE DW 181-182-183-184 EN User Manual

Page 25

background image

Installation and operating instructions DW 181 - 184

25

6 Technical

Data

DW 181

DW 182

DW 183

DW 184

Full-scale range (100% values)
Flow rate

m

3

/h 0.16…30

0.16…30

24…250

(US GPM) (0.7…132)

(0.7…132)

(106…1100)

Flow velocity m/s
(ft/s)

– –

– 0.4…4

(0.66…1.31)

Connection
Pipe thread G

3

/

4

” … 2”

– –

Flanges to DIN 2501

DN15- (DN65),

DN150/

(NFE 29203)

DN50/PN40 DN100,

DN125, PN16…PN25

(DN65/PN16) DN150/PN16

DN80/PN40,

DN200/PN10

Flanges to ANSI B16.5 –

1

/

2

”…2” (2

1

/

2

”) 3”

(2

1

/

2

”)…8” 6”

Class 150 lb/RF

Information on other standards and pressure ratings supplied on request

Measuring system
Measuring disc

C

C

with tapered tube

Nozzle with baffle

E

E

Baffle –

P

P

Indicator
Scale division 1 to 10

G

G

G

G

in flow units

A

A

A (

≤DN100 / 4”) –

Pipe run / flow direction
Vertical/upwards VU

VU

VU

Vertical/downwards VO

VO

VO

Horizontal/either way

H

H

H

H

Max. operating pressure*, ***
-

≤DN50 or 2”:

≤DN150 or 6”:

-

40bar or
580psig

40 bar or
580 psig

16 bar or
230 psig

25 bar or
365 psig

-

≥DN65 or 3”:

≥DN200 or 8”: -

16 bar or
230 psig

10 bar or
145 psig**

DN150 PN16

DN150 PN16

<13 bar (for
dangerous
fluids only –
group 1
Directive
67/548/CEE -)

<13 bar (for
dangerous fluids
only –group 1
Directive
67/548/CEE -)

DN80 PN40

DN80 PN40

<25 bar (for
dangerous
fluids only –
group 1
Directive
67/548/CEE -)

<25 bar (for
dangerous fluids
only –group 1
Directive
67/548/CEE -)

* Information on higher pressure levels supplied on request, ** PN 16 optional,
*** Subject to process connection used and flange temperature