KROHNE DW 181-182-183-184 EN User Manual
Page 25
Installation and operating instructions DW 181 - 184
25
6 Technical
Data
DW 181
DW 182
DW 183
DW 184
Full-scale range (100% values)
Flow rate
m
3
/h 0.16…30
0.16…30
24…250
–
(US GPM) (0.7…132)
(0.7…132)
(106…1100)
Flow velocity m/s
(ft/s)
– –
– 0.4…4
(0.66…1.31)
Connection
Pipe thread G
3
/
4
” … 2”
– –
–
Flanges to DIN 2501
–
DN15- (DN65),
DN150/
(NFE 29203)
DN50/PN40 DN100,
DN125, PN16…PN25
(DN65/PN16) DN150/PN16
DN80/PN40,
DN200/PN10
Flanges to ANSI B16.5 –
1
/
2
”…2” (2
1
/
2
”) 3”
(2
1
/
2
”)…8” 6”
Class 150 lb/RF
Information on other standards and pressure ratings supplied on request
Measuring system
Measuring disc
C
C
–
–
with tapered tube
Nozzle with baffle
E
E
–
–
Baffle –
–
P
P
Indicator
Scale division 1 to 10
G
G
G
G
in flow units
A
A
A (
≤DN100 / 4”) –
Pipe run / flow direction
Vertical/upwards VU
VU
VU
–
Vertical/downwards VO
VO
VO
–
Horizontal/either way
H
H
H
H
Max. operating pressure*, ***
-
≤DN50 or 2”:
≤DN150 or 6”:
-
40bar or
580psig
40 bar or
580 psig
16 bar or
230 psig
25 bar or
365 psig
-
≥DN65 or 3”:
≥DN200 or 8”: -
16 bar or
230 psig
10 bar or
145 psig**
DN150 PN16
DN150 PN16
<13 bar (for
dangerous
fluids only –
group 1
Directive
67/548/CEE -)
<13 bar (for
dangerous fluids
only –group 1
Directive
67/548/CEE -)
DN80 PN40
DN80 PN40
<25 bar (for
dangerous
fluids only –
group 1
Directive
67/548/CEE -)
<25 bar (for
dangerous fluids
only –group 1
Directive
67/548/CEE -)
* Information on higher pressure levels supplied on request, ** PN 16 optional,
*** Subject to process connection used and flange temperature