beautypg.com

KROHNE DW 181-182-183-184 EN User Manual

Page 12

background image

12

Installation and operating instructions DW 181 - 184


3.2.2 Type

A

indicator

The switch is adjusted by unlocking the adjustment screw (item 7) and repositioning the switch
support arm (item 8).
“A” graduated dial indicator assembly


1


Pointer

2 Dial

3 Following

magnet

4 Control

magnet

5 Mechanism

6 Switch

7 Adjustment

screw

8 Switch

support


3.3

Adjusting the limit switches - EEx d flow switch version


3.3.1 MS 12/BRX switch
The switch is adjusted by unscrewing the limit switch adjustment screw M8x10 (2) on top of the
pressure housing with a 4mm hexagon key. The switch (in its metal sheath) may then be
repositioned as required before retightening the screw. The original position is etched onto the
sheath.
MS 12/BRX switch assembly


1


MS 12/BRX switch

2

Limit switch adjustment
screw

3 Switch

sheath

4 Switch

magnet

5 Pressure

housing