Installation and operating instructions DW 181 - 184

Principle components


DW 18 Standard or EEx ia version

1

Indicator type G (linear scale) or A
(dial)

2 Equipment

label*

3

Flange (illustrated) or screwed
connection

4

Indicator cover locking pin

5

Flow direction arrow (DW183/4)

6

Wiring compartment cover

7 Gland

(plugged)

8

Cable fitting (PG 13.5)

9 Measuring

tube



DW 18 EEx d version

1 Equipment

labels*

2

MS 12/BRX switch housing

3

Cable fitting (to be supplied by the
customer)

4 PE

terminal

5

Flow direction arrow (on measuring
tube for DW181/2)

6

Socket set screw for adjusting
switch position

7 Pressure

housing

8

Equipment dog-tag (tag no., etc.)

9 Screw-on

connection



DW 18 HT (H3) version

1 Pressure

housing

2

Switch sheathed in a PTFE
cartridge

3 Measuring

tube

4

Electric cable in fibre glass
sheathing

5

MS 14 switch information label

6 Wiring

box

7

Cable fitting (PG 9)



* Equipment labels shown on next page