beautypg.com

KROHNE DW 181-182-183-184 EN User Manual

Page 27

background image

Installation and operating instructions DW 181 - 184

27

Special conditions for ATEX applications

Flow indicator DW18* EEx d
Authorized markings:

II 1/2 GD EEx d IIC T…* IP65 T…°C**,***

Temperature Class

Process temperature

Ambient temperature range

T6 / T80°C or 175°F**

T(fluid)

≤60°C or 140°F

-40…+50°C or -40…+120°F

T5 / T95°C or 200°F**

T(fluid)

≤80°C or 175°F

-40…+50°C or -40…+120°F

T4 / T130°C or 265°F**

T(fluid)

≤120°C or 250°F

-40…+60°C or -40…+140°F

T3 / T195°C or 380°F**

T(fluid)

≤150°C or 300°F

-40…+80°C or -40…+175°F


Flow indicator DW18* EEx ia

Authorized markings:

II 1 GD EEx ia IIC T…* IP65 T…°C**,***

Temperature Class

Process temperature

Ambient temperature range

T6 / T80°C or 175°F**

T(fluid)

≤60°C or 140°F

-40…+40°C or -40…+105°F

T5 / T95°C or 200°F**

T(fluid)

≤80°C or 175°F

-40…+40°C or -40…+105°F

T4 / T130°C or 265°F**

T(fluid)

≤120°C or 250°F

-40…+50°C or -40…+120°F

T3 / T195°C or 380°F**

T(fluid)

≤150°C or 300°F

-40…+80°C or -40…+175°F

* Maximum surface temperature of device
** T3, T4, T5 or T6 according to process temperature and ambient temperature
*** T195…80°C according to process temperature and ambient temperature


Viscosity
Standard mPa.s
lb/ft.s

≤30 or
≤20x10

-3

≤30 or
≤20x10

-3

≤30 or
≤20x10

-3

≤30 or
≤20x10

-3

Special version mPa.s
lb/ft.s

>30 or
>20x10

-3

>30 or
>20x10

-3

>30 or
>20x10

-3

>30 or
>20x10

-3

Repeatability
(switching point)

±3% ±3%

±3% ±3%

Measuring accuracy
(Indicator A)

±15% ±15%

±15%

(

≤DN100, 4”)

Protection category

IP 55 (standard version)

to EN 60529 / IEC 529

IP 44 (high-temperature version)

IP 65 (ATEX version)

Electromagnetic
compatibility (EMC)

EN 50081-1 and 50082-2

Limit switches
Type

Number and description

K1

1 N/C* or 1 N/O* switch (bistable) or 3-wire SPDT (change over)

K2

1 N/C* or 1 N/O* switch (bistable) or 3-wire SPDT (change over)

2 N/C* or 2 N/O* switches also possible in conjunction with high-
temperature version H3

KV1, KV2

1,2 changeover switches (bistable) with amplifier relay

Type

Max. switching capacity rating

K1, K2 (standard)

max. 14 VA (max. 350 V AC; max. 0.4 A)

K1, K2 with changeover max. 3 VA (max. 28 V DC; max. 0.25 A)
EEx d characteristics

max. dissipation (Ex d housing): 20 VA; max. 380 V AC; max. 1.5 A

EEx ia safety values

Ii < 500 mA, Ci = 0 nF, Li = 0 µH

Reed switch, HT

18 VA (max. 220 V; max. 0.8 A)

KV1, KV2

max. 2000 VA (max. 250 V AC, max. 8 A)

Amplifier relay characteristics
Power supply

240/110/48/24 V AC, 110/48/24 V DC

Response time

5…12 ms

* Refer to section 2: Electrical connections for definition.