Mounting the weld end (see previous figure)

• Open a Ø 48.5 mm / 1.91" hole in the process pipe.
• Cut the weld end to get the sensor head at least 5 mm / 0.2" from the pipe wall.
• Weld the weld end to the pipe.
• Stabilize the weld end using 3 mm / 0.1" strip iron according to the figure above.

Mounting the optional threaded nipple in a saddle

• Mount the saddle on the pipe according to the saddle manufacturer's instructions.
• Thread the nipple into the saddle.
• Use flaxen hair and joint paste. Be aware to get the correct distance from the pipe wall to the

valve.

Figure 3-7: Mounting of weld end with strip iron

1 Weld end
2 Weld
3 Process pipe