Page 4 of 4
Specifications
Wetted materials
316 Stainless steel, Viton
®
Transduction principle
Integrated silicon strain gauge bridge
Voltage input
11.6 – 40 (absolute maximum) VDC
Signal current
4 – 20 mA (typical throughout pressure range)
Operating temperature
5º to 30ºC (41º to 86ºF)
Storage temperature
-40º to 125ºC (-40º to 257ºF)
Min. warmup time
50 milliseconds
PXD-261
Dimensions
0.86” dia., 8.5” long (2.2 x 21.6 cm)
Weight
1 lb. (0.45 kg)
Accuracy
±0.05% of full scale at 15ºC (59ºF)
Ranges
Pressure
Max. Usable Depth
15 PSIG/PSIA
35 ft /11 m water
20 PSIG/PSIA
46 ft /14 m water
30 PSIG/PSIA
69 ft /21 m water
50 PSIG/PSIA
115 ft /35 m water
100 PSIG/PSIA
231 ft /70 m water
250 PSIG
577 ft /176 m water
Overpressure tolerance
2X full range
PXD-461
Dimensions
0.7” diameter, 8.5” long (1.78 x 21.6 cm)
Weight
0.5 lb (0.22 kg)
Accuracy
±0.04% of full scale at 15ºC (59ºF)
Ranges
Pressure
Max. Usable Depth
500 PSIA
1153 ft / 352 m water
1000 PSIA
2307 ft / 703 m water
Overpressure tolerance
1.5X full range
Cable
Wetted materials
316 Stainless steel, Viton
®
Vented: FEP* or polyurethane
Non-vented: high-density polyethylene (HDPE)
Size
0.25” (6.7 mm) OD nominal
Max. length
4500 ft (1372 m)
Reels
Plastic: up to 350 ft (106 m) capacity
Small Steel: up to 450 ft (137 m) capacity
Large Steel: up to 1500 ft (457 m) capacity
0010000 rev. 004 06/07
How to Contact Us
Technical Support:
800 446 7488
Toll-free 24 hours a day in the U.S. and Canada
Address:
In-Situ Inc.
221 East Lincoln Ave.
Fort Collins, CO 80524 USA
Phone:
970 498 1500
Fax:
970 498 1598
Internet:
www.in-situ.com
e-mail:
To Obtain Repair Service (U.S.)
If you suspect the transducer is malfunctioning and repair is re-
quired, you can help assure efficient servicing as follows:
1
Call or e-mail In-Situ Technical Support ([email protected]).
Have the product model and serial number handy.
2
Be prepared to describe the problem, including how the instru-
ment was being used and the conditions noted at the time of the
malfunction.
3
If Tech Support determines that service is needed, they will ask
that your company pre-approve a specified dollar amount for
repair charges. When the pre-approval is received, Tech Support
will assign an RMA (Return Material Authorization) number.
4
Clean the probe and cable. Decontaminate thoroughly if it has
been used in a toxic or hazardous environment.
5
Pack the transducer in its original shipping box, if possible.
6
Mark the RMA number clearly on the outside of the box.
7
Send the package, shipping prepaid, to
In-Situ, Inc.
ATTN: Repairs
221 East Lincoln Ave.
Fort Collins, CO 80524
The warranty does not cover damage during transit. In-Situ recom-
mends the customer insure all shipments. Warranty repairs will be
shipped back prepaid.
Outside the U.S.
Contact your international In-Situ distributor for repair and service
information.
** FEP = fluorinated ethylene propylene, the generic equivalent of DuPont Teflon®.