beautypg.com

GW Instek APS-9000 Series User Manual

Page 4

background image

APS-9301 & APS-9501 & APS-9102 User’s Manual

6

5.Output Enabled and Disabled Operation:

Press the key of ‘OUTPUT’. If the indicator of output lights, the output of

APS-9301/9501/9102 is enabled, all the LED display will show the output
value (reading value). Otherwise, the output function is disabled, and the
LED display will show the setting value. Press the ‘OUTPUT’ key again
to change the mode.

6.Lock Function:

Press the key of ‘LOCK’. If the indicator of lock lights, all the keys are
Locked (except the alarm reset). This function is good for avoiding any
mistakes of key pressed during operation. Press again to change the mode.

7.Alarm Reset:

If there is over current happened, APS-9301/9501/9102 would be shut

down and buzz immediately. You must press the key of ‘ALARM
RESET’
to clear the fault of over current and stop the buzz. In addition,
the key of ‘OUTPUT’ have to be pressed to get the normal output voltage
again.

8.Memory Function:

As APS-9301/9501/9102 is equipped with EEPROM, the latest setting will
be memorized after the unit is turned off. If the APS-9301/9501/9102 is
turned on again, the latest setting will be displayed.

9.Save/Recall Function:

Press the key of ‘S/R’, if the indicator of SAVE/RECALL doesn’t light,
Press any one of keys ‘MEM1’ ‘MEM2’ ‘MEM3’ and ‘MEM4’ for 0.2
seconds, the current output setting will be saved. If the indicator of
SAVE/RECALL lights, press any one of keys ‘MEM1’ ‘MEM2’ ‘MEM3’
and ‘MEM4’ for 0.2 seconds, the setting saved last time via the same key
will be recalled as current settin

APS-9301 & APS-9501 & APS-9102 User’s Manual

7