beautypg.com

GW Instek APS-9000 Series User Manual

Page 2

background image

APS-9301 & APS-9501 & APS-9102 User’s Manual

2

sel ect swi t ch

2 3 0 V

2.

Installatio

n

1.Before installation, please make sure the AC input voltage is correct.

a.The AC input voltage of APS-9301/9501 is either 115V or 230V,

which can be selected. The select switch is located on the rear panel.

b. The AC input voltage of APS-9102 is fixed either at 115V or 230V,

For safety reason,Do not make any change by you own to avoid
damaging the instrument.

2.Before plugs input power cord to the suitable outlet or connects the

input wires, please make sure all the APS-9301/9501/9102’s breakers
are turned off. It will avoid the unnecessary accident or damage to
APS-9301/9501/9102.

3.Plugs the input power cord to the suitable outlet or connects the input

wires/cable to the input terminal block which is located inside panel of
APS-9301/9501/9102. Please make sure the connections are very tight
which may avoid some problem happening.

4.Please make sure the input tolerance of this APS-9301/9501/9102 is

within ±15% of rated voltage (see figure 1)

Figure 1.

Max
Output
Voltage

150/300

120/240

100/200

85

90

95

115

100

% of Rate

Input Voltage

120/240

APS-9301 & APS-9501 & APS-9102 User’s Manual

3

5.The size of input wire and output wire.

Input Wire Size

Model

115V

230V

Output Wire Size

APS-9301/9501

AWG#14

0.75mm

2

AWG#18

APS-9102

AWG#12

2* AWG#18

6.An AC power cord is packaged in the unit of APS-9301/9501 as

accessory.

7.The Selection of Output Test Lead:

For safety assurance, please select the adequate output test
lead according to the following list:

Conductor

UL

(CSA)
Model

Wire

No.

AWG

Component

pc/mm

Cross

Section

Area

(mm)

2

Outer

Diameter

mm

Maximum

Conductive

Resistor

Ω/km

Permissible

Current
A(amp)

24

11/0.16

0.22

0.64

88.6

7.64

22

17/0.16

0.34

0.78

62.5

10.0

20

21/0.18

0.53

0.95

39.5

13.1

18

34/0.18

0.87

1.21

24.4

17.2

16

26/0.254

1.32

1.53

15.6

22.6

14

41/0.254

2.08

2.03

9.90

30.4

12

65/0.254

3.29

2.35

6.24

40.6

1015

TEW

(Twisted

Wire)

10

65/0.32

5.23

3.00

3.90

55.3

Remark:

1. The ambient temperature of “Permissible Current” is at

40℃, the withstanding temperature of conductor is at
105℃ according to the condition of the distributed
single wire.

2. The permissible current listed as above is suggested to

be used under 70%.

3. When the current value exceeds above suggestive list,

can select more wires used in parallel according to
above list.