VisorALARM Manager – Quick Guide

8

Doc. DM380-I

Rev. 3.0

6.

Modifying the mIP parameters

The “mIP” tab accesses the list of registered mIPs (see Fig 7). Operations that can be
executed with the selected mIP are “Update” and “Delete”. Updating a mIP parameter is
carried out by selecting the required mIP from the list and changing the necessary parameter
value. Subsequently click on the “Update” button as indicated in Fig 3 so the change is saved
in the VisorALARM and transmitted to the mIP. The updating operation can be executed if
the mIP is connected to the VisorALARM. Deregistering a mIP in the VisorALARM is done
by selecting the mIP from the mIP list and clicking on the “Delete” button. A mIP connected
to a VisorALARM and deleted immediately, loses connectivity.

Figure 7


The next table explains briefly each mIP parameter:

Parameter

Description

Account identifier

This is the mIP/IPDACT device account. It must match the
Control Panel Account number

Serial number (Read Only)

mIP/IPDACT serial number

Receiver Port

UDP port on the receiver where the device sends the
registration, supervision and alarm data packets

Telephone length

Number of digits that the Control Panel dials for the Central