beautypg.com

SilentKnight VisorAlarm Manager User Manual

Page 4

background image

VisorALARM Manager – Quick Guide

4

Doc. DM380-I

Rev. 3.0

Printer: Line Speed

Baud rate for the Serial Printer connected to WAN2/PRN

Printer: Data bits

Number of data bits for the Serial Printer connected to
WAN2/PRN

Printer: Stop bits

Number of stop bits for the Serial Printer connected to
WAN2/PRN

Printer: Flow Control

Specifies if the communications with the Serial Printer require
Hardware Flow Control

Internet Link: Monitoring
address

IP Address for a server in Internet used to check that the
receiver has Internet Access

Internet Link: Frequency

Number of seconds between two polls from the receiver to
the Monitoring Address.

Enable monitor events

Enables/Disables monitoring events in the receiver

Serial Port: Line Speed

Baud rate for the Serial Port where automation software is
connected

Serial Port: Data bits

Number of data bits for the Serial Port where automation
software is connected

Serial Port: Stop bits

Number of stop bits for the Serial Port where automation
software is connected

Serial Port: Flow Control

Specifies if the communications with the Serial Port where
automation software is connected require Hardware Flow
Control

Serial Port: Receiver Type

Emulated receiver, the currently supported emulation types
are Ademco 685, Surgard MLR2000, Surgard DLR2 and
Radionics 6500.

Serial Port: Receiver Identifier

Number for this receiver in the automation software

Serial Port: Line Identifier

Number for the unique line of this receiver in the automation
software.

Serial Port: Link Test Timer

Specifies the time interval that the receiver waits between
polls to the automation software through the serial port.

Serial Port: Enable
ACK/NACK

For the Ademco 685 emulation specifies if the VisorALARM
receiver must wait for acknowledgments when a signal is sent
to the automation software through the serial port.

Serial Port: ACK Char

ACK char used for the Acknowledgement when using
Radionics 6500 emulation

Serial Port: Header Char

Header char used for start of frames when using Radionics
6500 emulation

Serial Port:: Termination Char

Termination char used to end the frames when using
Radionics 6500 emulation

Serial Port: NACK Char

NACK char used for the Negative acknowledgements when
using Radionics 6500 emulation

User

The user name for management purposes. This is always
“manager”

Password

Password for the manager

UD authentication

User and Password to be used for access to the remote UD
server.