Detcon CXT-DM User Manual
Page 47
Model CXT-DM
Gas
GasName
Part Number
Response Time
(seconds)
SpanDrift
Temperature
Range °C
Humidity
Range%
Warranty
N
2
H
4
Hydrazine
371-262600-001
T90<120
<5%signal
loss/month
-10 to+40
10 to 95
1 year
H
2
(ppm)
Hydrogen
371-848400-100
T90=30
<2%signal
loss/month
-20 to+50
15 to 90
2 years
H
2
(LEL)*
Hydrogen
371-050500-04P
T90<60
<2%signal
loss/month
-40 to+40
5 to 95
2 years
HBr
Hydrogen
Bromide
371-090800-030
T90<70
<3%signal
loss/month
-20 to+40
10 to 95
1.5 years
HCl
Hydrogen
Chloride
371-090900-030
T90<70
<2%signal
loss/month
-20 to+40
10 to 95
1.5 years
HCN
Hydrogen
Cyanide
371-131300-030
T90<40
<5%signal
loss/month
-40 to+40
5 to 95
2 years
HF
Hydrogen
Fluoride
371-333300-010
T90<90
<10%signal
loss/month
-20 to+35
10 to 80
1.5 years
H
2
S
Hydrogen
Sulfide
371-242400-100
T80<30
<2%signal
loss/month
-40 to+50
15 to 90
2 years
CH
3
OH
Methanol
371-12EE00-100
T90<140
<5%signal
loss/year
-20 to+50
15 to 90
2 years
CH
3
SH
Methyl
Mercaptan
371-24EK00-100
T90<45
<2%signal
loss/month
-40 to+50
15 to 90
2 years
NO
Nitric Oxide
371-949400-100
T90=10
<2%signal
loss/month
-20 to+50
15 to 90
3 years
NO
2
Nitrogen
Dioxide
371-646400-010
T90<40
<2%signal
loss/month
-20 to+50
15 to 90
2 years
O
3
Ozone
371-999900-001
T90<120
<1%signal
loss/month
-10 to+40
10 to 95
2 years
COCl
2
Phosgene
371-414100-001
T90<120
<1%signal
loss/month
-20 to+40
10 to 95
1.5 years
PH3
Phosphine
371-192000-005
T90<30
<1%signal
loss/month
-20 to+40
20 to 95
1.5 years
SiH
4
Silane
371-232300-050
T90<60
<1%signal
loss/month
-20 to+40
20 to 95
1.5 years
SO
2
Sulfur Dioxide 371-555500-020
T90=20
<2%signal
loss/month
-20 to+50
15 to 90
2 years
1
The last three digits of the Part Number are the range of the sensor cell. I.E. “-100” is a 100ppm range.
CXT-DM Instruction Manual
Rev. 1.6
Page 43 of 52