4 mechanical specifications, 2 sensor specific data, Mechanical specifications – Detcon CXT-DM User Manual
Page 46: Sensor specific data, Table 3 sensor specific data

Model CXT-DM
9.1.4 Mechanical Specifications
Length:
ITM - 5.165 inches (131 mm), 8.5 inches (215mm) with Splash Guard
Width:
2.2 inches (55 mm)
Weight:
2.5 lbs (1.2 Kg)
Mechanical Connection:
¾” Male NPT threaded connection with locking nut
Electrical Connection:
four 18 gauge wire leads - 5.5” long with RF Cable terminated at SMA
9.2 Sensor Specific Data
Table 3 Sensor Specific Data
Gas
GasName
Part Number
Response Time
(seconds)
SpanDrift
Temperature
Range °C
Humidity
Range%
Warranty
O
2
Oxygen
371-343400-025
T95<30
<5%signal
loss/year
-20 to+50
15 to 90
2 years
C
2
H
3
O
Acetaldehyde
371-12EA00-100
T90<140
<5%signal
loss/year
-20 to+50
15 to 90
2 years
C
2
H
2
Acetylene
371-12EG00-100
T90<140
<5%signal
loss/year
-20 to+50
15 to 90
2 years
NH
3
Ammonia
371-171700-100
T90<90
<2%signal
loss/month
-20 to+50
15 to 90
2 years
AsH
3
Arsine
371-191900-001
T90<60
<5%signal
loss/month
-20 to+40
20 to 95
1.5 years
Br
2
Bromine
371-747500-005
T90<60
<2%signal
loss/month
-20 to+50
15 to 90
2 years
C
4
H
6
Butadiene
371-12EB00-100
T90<140
<5%signal
loss/year
-20 to+50
15 to 90
2 years
CO
Carbon
Monoxide
371-444400-100
T90=30
<5%signal
loss/year
-40 to+50
15 to 90
3 years
Cl
2
Chlorine
371-747400-010
T90<60
<2%signal
loss/month
-20 to+50
15 to 90
2 years
ClO
2
(>10ppm)
Chlorine
Dioxide
371-777700-001
T90<60
<2%signal
loss/month
-20 to+50
15 to 90
2 years
ClO
2
(<=10ppm)
Chlorine
Dioxide
371-282800-050
T90<120
<1%signal
loss/month
-20 to+40
10 to 95
2 years
B
2
H
6
Diborane
371-192100-005
T90<60
<5%signal
loss/month
-20 to+40
20 to 95
1.5 years
C
2
H
5
OH
Ethanol
371-12EO00-100
T90<140
<5%signal
loss/year
-20 to+50
15 to 90
2 years
C
2
H
5
SH
Ethyl
Mercaptan
371-24EZ00-100
T90<45
<2%signal
loss/month
-40 to+50
15 to 90
2 years
C
2
H
4
Ethylene
371-12ED00-100
T90<140
<5%signal
loss/year
-20 to+50
15 to 90
2 years
C
2
H
4
O
Ethylene Oxide 371-12EJ00-100
T90<140
<5%signal
loss/year
-20 to+50
15 to 90
2 years
F
2
Fluorine
371-272700-001
T90<80
<5%signal
loss/year
-10 to+40
10 to 95
1.5 years
CH
2
O
Formaldehyde 371-12EP00-100
T90<140
<5%signal
loss/year
-20 to+50
15 to 90
2 years
GeH
4
Germane
371-232500-002
T90<60
<1%signal
loss/month
-20 to+40
20 to 95
1.5 years
1
The last three digits of the Part Number are the range of the sensor cell. I.E. “-100” is a 100ppm range.
CXT-DM Instruction Manual
Rev. 1.6
Page 42 of 52