Model CX-DM

1.2 Modular Design


The CX-DM sensor assembly is completely modular and is composed of four parts (Figure 3).

1. CX-DM Intelligent Transmitter Module (ITM)
2. Plug-in Electrochemical Sensor (varies by gas type and range)
3. CX Series Bottom Housing
4. Splash Guard

CX-DM Bottom

Housing Assembly

Plug-in Replaceable

Sensor

Intelligent Transmitter Module (ITM)
Micro-processor controlled circuit

encapsulated in an Explosion proof
housing.

Magnetic

Programming Switches

Splash Guard

3

4

" NPT Locking

Nut

Figure 3 Sensor Assembly Breakaway

NOTE

All metal components are constructed from electro polished 316 Stainless Steel to
maximize corrosion resistance in harsh environments.

CX-DM Intelligent Transmitter Module

The transmitter module is microprocessor-based and attached to the explosion proof junction box. Circuit
functions include an intrinsically safe barrier, on-board power supply, microprocessor, magnetic programming
switches, and a linear 4-20mA DC output. Magnetic program switches (located on either side of the ITM) are
activated by a hand-held magnetic programming tool, allowing non-intrusive operator interface with the
transmitter module. Electrical classifications are Class I, Div 1, Groups B, C, and D.









Figure 4 Functional Block Diagram

Field Replaceable Sensor

Detcon

ꞌs electrochemical gas sensors are field proven, plug-in sensors with over-sized gold-plated connections

that eliminate corrosion problems. The sensor can be easily accessed and replaced in the field by releasing the
locking screw and unthreading the splashguard adapter assembly. Detcon

ꞌs toxic sensors have a long shelf life

and supported by an industry-leading warranty.

I/O

Circuit

Protection

mA Output

Power In

Power

supplies

Micro-

Processor

Intrinsically

Safe Barrier


Plug-In

Sensor

Modbus Output

CX-DM Instruction Manual