Detcon CX-DM User Manual
Page 37
Model CX-DM
Gas
GasName
Part Number
Response
Time
(seconds)
SpanDrift
Temperatur
e Range °C
Humidity
Range%
Warranty
HF
Hydrogen
Fluoride
371-333300-010
T90<90
<10%signal
loss/month
-20 to+35
10 to 80 1.5 years
H
2
S
Hydrogen Sulfide 371-242400-100
T80<30
<2%signal
loss/month
-40 to+50
15 to 90
2 years
CH
3
OH
Methanol
371-12EE00-100
T90<140
<5%signal loss/year -20 to+50
15 to 90
2 years
CH
3
SH
Methyl
Mercaptan
371-24EK00-100
T90<45
<2%signal
loss/month
-40 to+50
15 to 90
2 years
NO
Nitric Oxide
371-949400-100
T90=10
<2%signal
loss/month
-20 to+50
15 to 90
3 years
NO
2
Nitrogen Dioxide 371-646400-010
T90<40
<2%signal
loss/month
-20 to+50
15 to 90
2 years
O
3
Ozone
371-999900-001
T90<120
<1%signal
loss/month
-10 to+40
10 to 95
2 years
COCl
2
Phosgene
371-414100-001
T90<120
<1%signal
loss/month
-20 to+40
10 to 95 1.5 years
PH3
Phosphine
371-192000-005
T90<30
<1%signal
loss/month
-20 to+40
20 to 95 1.5 years
SiH
4
Silane
371-232300-050
T90<60
<1%signal
loss/month
-20 to+40
20 to 95 1.5 years
SO
2
Sulfur Dioxide
371-555500-020
T90=20
<2%signal
loss/month
-20 to+50
15 to 90
2 years
CX-DM Instruction Manual
Rev. 1.3
Page 33 of 40