beautypg.com

Detcon CX-DM User Manual

Page 37

background image

Model CX-DM

Gas

GasName

Part Number

1

Response

Time

(seconds)

SpanDrift

Temperatur

e Range °C

Humidity

Range%

Warranty

HF

Hydrogen
Fluoride

371-333300-010

T90<90

<10%signal

loss/month

-20 to+35

10 to 80 1.5 years

H

2

S

Hydrogen Sulfide 371-242400-100

T80<30

<2%signal

loss/month

-40 to+50

15 to 90

2 years

CH

3

OH

Methanol

371-12EE00-100

T90<140

<5%signal loss/year -20 to+50

15 to 90

2 years

CH

3

SH

Methyl
Mercaptan

371-24EK00-100

T90<45

<2%signal

loss/month

-40 to+50

15 to 90

2 years

NO

Nitric Oxide

371-949400-100

T90=10

<2%signal

loss/month

-20 to+50

15 to 90

3 years

NO

2

Nitrogen Dioxide 371-646400-010

T90<40

<2%signal

loss/month

-20 to+50

15 to 90

2 years

O

3

Ozone

371-999900-001

T90<120

<1%signal

loss/month

-10 to+40

10 to 95

2 years

COCl

2

Phosgene

371-414100-001

T90<120

<1%signal

loss/month

-20 to+40

10 to 95 1.5 years

PH3

Phosphine

371-192000-005

T90<30

<1%signal

loss/month

-20 to+40

20 to 95 1.5 years

SiH

4

Silane

371-232300-050

T90<60

<1%signal

loss/month

-20 to+40

20 to 95 1.5 years

SO

2

Sulfur Dioxide

371-555500-020

T90=20

<2%signal

loss/month

-20 to+50

15 to 90

2 years

CX-DM Instruction Manual

Rev. 1.3

Page 33 of 40