beautypg.com

2 temperature compensation – register 40012, Temperature compensation – register 40012 – Detcon CX-DM User Manual

Page 27

background image

Model CX-DM

Bit 4

– Reserved

Bit 3

– Reserved

Bit 2 – Temperature Fault
Bit 1 – Auto Span Fault
Bit 0

– Global Fault

4.2.2 Temperature Compensation – Register 40012


The CX-DM implements temperature compensation for certain gas types. The possible values for this register
are as follows:

0 = No temperature compensation
1 = CO - temperature compensation
2 = H

2

- temperature compensation

3 = NH

3

- temperature compensation

4 = ETO - temperature compensation
5 = ETHYLENE - temperature compensation
6 = VINYL CHLORIDE - temperature compensation
7 = METHANOL - temperature compensation
8 = ETHANOL - temperature compensation
9 = ACRYLONITRILE - temperature compensation
10 = ACETALDEHYDE - temperature compensation
11 = CL

2

- temperature compensation




CX-DM Instruction Manual

Rev. 1.3

Page 23 of 40