Introduction, 1 description, Figure 1 sensor assembly front view – Detcon FP-524D-HRT User Manual
Page 5
![background image](/manuals/366717/5/background.png)
Model FP-524D-HRT
FP-524D-HRT Instruction Manual
Rev. 0.1
Page 1 of 48
1. Introduction
1.1 Description
Detcon Model FP-524D-HRT LEL Combustible sensors are non-intrusive “Smart” sensors designed to detect
and monitor combustible gases in air. Range of detection is 0-100% LEL (Lower Explosive Limit). The
sensor features an LED display of current reading, fault, and calibration status. The Sensor is equipped with a
HRT Bridge Interface, analog 4-20mA output.
The HRT Bridge interface provides bi-directional digital
communication with HART
®
-enabled devices. A primary feature of the sensor is its method of automatic
calibration, which guides the user through each step via fully scripted instructions displayed on the LED
display.
The microprocessor-supervised electronics are packaged as a plug-in replaceable Transmitter Module that is
housed in an explosion proof junction box. The Transmitter Module includes a four character alpha/numeric
LED used to display sensor readings, and the sensor’s menu driven features when the hand-held programming
magnet is used.
PGM
1
PGM
2
MODEL
FP-524D
HOUSTON, TEXAS
FLT
1
2
CAL
MicroSafe LEL Gas Sensor
ALM ALM
TM
Figure 1 Sensor Assembly Front View
Catalytic Bead (Pellistor) Sensor Technology
The sensor technology is a poison-resistant catalytic bead type. Catalytic bead sensors show a strong response
to a long list of combustible gases. The sensor is supplied as a matched-pair of detector elements mounted in a
plug-in replaceable module. One bead is a catalytically active detector and the other is a non-active reference
detector. Each detector consists of a fine platinum wire coil embedded in aluminum oxide. A catalytic
mixture is applied to the active detector while the reference detector is treated so that oxidation of the gas does
not occur. This technique is referred to as non-selective and may be used to monitor most any combustible
gas.
Detcon catalytic bead sensors are specifically designed to be resistant to poisons such as sulfides,
chlorides, and silicones.
The sensors are characteristically stable and capable of providing reliable
performance for periods exceeding 5 years in most industrial environments.