beautypg.com

Appendix, 1 specifications – Detcon FP-524D-HRT User Manual

Page 49

background image

Model FP-524D-HRT

FP-524D-HRT Instruction Manual

Rev. 0.1

Page 45 of 48

9. Appendix

9.1 Specifications

Sensor Type:

Continuous diffusion/adsorption type
Matched-Pair Catalytic Bead type
True plug-in replaceable type

Sensor Life:

3-5 years typical

Measuring Ranges:

0-100% LEL

Accuracy/ Repeatability:

± 3% LEL in 0-50% LEL range, ± 5% LEL in 51-100% LEL range

Response Time:

T50 < 10 seconds, T90 < 30 seconds

Performance Testing:

Complies with CSA C22.2 No. 152-M1984, ANSI/ISA S12.13

Electrical Classification:

CSA and US (NRTL)
Class I, Division 1, Groups B, C, D

Approvals:

C

CSA

US

Applicable Standards

CSA C22.2 No. 30-M1986
CSA C22.2 No. 142-M1987
CSA C22.2 No. 152-M1984
UL Std. No. 916
UL Std. No.1203
ANSI/ISA S12.13

Warranty:

Electronics – 2 years
Sensor – 2 years

Environmental Specifications

Operating Temperature:

-40°C to +75°C

Storage Temperature:

-40°C to +75°C

Operating Humidity:

0-100% RH (Non-condensing)

Operating Pressure:

Ambient ± 10%

Electrical Specifications

Input Voltage:

12-28 VDC

Power Consumption:

Normal operation = 68mA (<1.7 watt); Maximum = 87mA (2 watts)

RFI/EMI Protection:

RFI Complies with ISA 92.0.01

Output:

Linear 4-20mA DC current with HART

®

Communication Protocol